CVE-2017-12736

mediumPriorität · verfolgen · 23OT-Risiko · erhöhtEPSS 0.011 · 65. PerzentilDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.07% (65th) EPSS
CVSS 5.8 · medium
Is it mine?
1,014 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · siemens_psirt

EPSS · bewertet 2026-10-27

After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.8
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.8–8.8

v2.05.8mediumAV:A/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USAusnutzbarkeit 6.5 · Auswirkung 6.4
v3.08.8highCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · NVD / NIST USAusnutzbarkeit 2.8 · Auswirkung 5.9
v3.18.8highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.18.8highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.18.8highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEAusnutzbarkeit 2.8 · Auswirkung 5.9
v3.18.8highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.18.1highCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (1,014)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-856721SSA-856721: Vulnerability in RUGGEDCOM Discovery Protocol (RCDP) of Industrial Communication Devices2017-09-28csaf · siemens_psirtDE

    The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to exploit the vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • ICSA-17-271-01BSiemens Ruggedcom ROS, SCALANCE2017-09-28icsa · cisa_csaf_otUS

    The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to exploit the vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2017-12-26geändert 2026-06-17
08

Referenzen (15)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan