CVE-2017-12722
mediumPriorität · verfolgen · 22EPSS 0.024 · 84. PerzentilEUUSEPSS · bewertet 2026-10-27
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Ein Hersteller-Fix ist verfügbar.
- BehobenMedfusion 4000 Wireless Syringe Infusion Pumpcisa_csaf_ot
Email: info.asd@smiths-medical.com
- MitigationMQX RTOScisa_csaf_ot
NXP released MQX, Version 5.1 on January 31, 2018, which addresses both vulnerabilities.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–medium · 3.7–5.3
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (12)
Betroffene Produkte und Versionsbereiche.
- n/a Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump≤ Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pumpenisa_euvdEU
- smiths-medical medfusion 4000 wireless syringe infusion pump= 1.1nvdUScpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:*:*:*:*:*:*:*:*
- smiths-medical medfusion 4000 wireless syringe infusion pump= 1.5nvdUScpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:*:*:*:*:*:*:*:*
- smiths-medical medfusion 4000 wireless syringe infusion pump= 1.6nvdUScpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:*:*:*:*:*:*:*:*
Advisories (2)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-17-285-04ANXP Semiconductors MQX RTOS (Update A)2017-10-12icsa · cisa_csaf_otUS
ATTENTION: Remotely exploitable/low skill level to exploit.
- ICSMA-17-250-02ASmiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)2017-09-07icsa · cisa_csaf_otUS
This updated advisory is a follow-up to the original advisory titled ICSMA-17-250-02 Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities that was published September 7, 2017, on the NCCIC/ICS-CERT web site.
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (10)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.securityfocus.com/bid/100665cnnvd
- http://www.securityfocus.com/bid/101252cnnvd
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02Acnnvd
- https://www.smiths-medical.com/Patchcnnvd
- http://www.securityfocus.com/bid/100665enisa_euvd
- http://www.securityfocus.com/bid/101252enisa_euvd
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02Aenisa_euvd
- http://www.securityfocus.com/bid/100665Third Party AdvisoryVDB Entrynvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan