CVE-2016-8358
mediumPriorität · verfolgen · 34EPSS 0.005 · 43. PerzentilEUUSEPSS · bewertet 2026-10-27
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationCADD-Solis Medication Safety Softwarecisa_csaf_ot
Smiths Medical has released new versions of the CADD-Solis Medication Safety Software, which mitigates the identified vulnerabilities. The new versions of Smiths Medical’s CADD-Solis Medication Safety Software are Version 3.2, which is distributed within the continental US, and Version 4.1, which is released outside the continental US.
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 6–8.5
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (10)
Betroffene Produkte und Versionsbereiche.
- n/a Smiths-Medical CADD-Solis Medication Safety Software through 3.1≤ Smiths-Medical CADD-Solis Medication Safety Software through 3.1enisa_euvdEU
- smiths-medical cadd-solis medication safety software= 1.0nvdUScpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:*:*:*:*:*:*:*:*
- smiths-medical cadd-solis medication safety software= 2.0nvdUScpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:*:*:*:*:*:*:*:*
- smiths-medical cadd-solis medication safety software= 3.0nvdUScpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:*:*:*:*:*:*:*:*
- smiths-medical cadd-solis medication safety software= 3.1nvdUScpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSMA-16-306-01Smiths Medical CADD-Solis Medication Safety Software Vulnerabilities2016-08-05icsa · cisa_csaf_otUS
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
auch bekannt als (3)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (7)
Externe Belege — Patches, Meldungen, Analysen.
- http://www.securityfocus.com/bid/94630cnnvd
- https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01cnnvd
- https://www.smiths-medical.com/Patchcnnvd
- http://www.securityfocus.com/bid/94630enisa_euvd
- https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01enisa_euvd
- http://www.securityfocus.com/bid/94630Third Party AdvisoryVDB Entrynvd
- https://ics-cert.us-cert.gov/advisories/ICSMA-16-306-01Third Party AdvisoryUS Government Resourcenvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan