CVE-2016-10395
mediumPriorität · verfolgen · 31EPSS 0.004 · 34. PerzentilEURUUSEPSS · bewertet 2026-10-27
In FlexNet Publisher versions before Luton SP1 (11.14.1.1) running FlexNet Publisher Licensing Service on Windows platform, a boundary error related to a named pipe within the FlexNet Publisher Licensing Service can be exploited to cause an out-of-bounds memory read access and subsequently execute arbitrary code with SYSTEM privileges.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationCitectHistoriancisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationCitectSCADAcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Modicon Buildercisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Power Monitoring Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Power SCADA Operationscisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEnergy Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationPlantStruxure PEScisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationSCADA Expert Vijeo Citect / CitectSCADAcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationStruxureWare Power Monitoring Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationVijeo Historian/CitectHistoriancisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–critical · 6.8–10
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (25)
Betroffene Produkte und Versionsbereiche.
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-18-144-01Schneider Electric Floating License Manager2018-05-24icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could cause a denial of service, allow arbitrary execution of code with system level privileges, or send users to arbitrary websites.
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (14)
Externe Belege — Patches, Meldungen, Analysen.
- https://secuniaresearch.flexerasoftware.com/advisories/76368/cnnvd
- https://www.flexerasoftware.com/Patchcnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-144-01enisa_euvd
- https://secuniaresearch.flexerasoftware.com/advisories/76368/enisa_euvd
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-managerenisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/enisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/enisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/enisa_euvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan