CVE-2015-8362

highPriorität · verfolgen · 41OT-Risiko · erhöhtEPSS 0.047 · 92. PerzentilEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
4.67% (92nd) EPSS
CVSS 10 · high
Is it mine?
63 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · bewertet 2026-10-27

The setUpSubtleUserAccount function in /bin/bw on Harman AMX devices before 2015-10-12 has a hardcoded password for the BlackWidow account, which makes it easier for remote attackers to obtain access via a (1) SSH or (2) HTTP session, a different vulnerability than CVE-2016-1984.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationDVX-2100HD-SP-T Mastercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationDVX-21xxHD-SP (-T)cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationDVX-31xxHD-SP (-T)cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationEnova DGX 100 NX Series Mastercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationEnova DGX 8/16/32/64 NI Series Mastercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationEnova DGX 8/16/32/64 NX Series Mastercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationEnova DVX-x2xxcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationME260/64 Duetcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationMassio ControlPads MCP-10xcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-2000cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-2100cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-2100 with ICSNetcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3000cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3100cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3100 with ICSNetcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3100/256cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3100/256 with ICSNetcisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-3101-SIG Master Controllercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-4000cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-4100cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-4100/256cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-700cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-900 Master Controllers (32M RAM)cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNI-900 Master Controllers (64M RAM)cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNX-1200cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNX-2200cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNX-3200cisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

  • MitigationNX-4200 NetLinx Controllercisa_csaf_ot

    AMX has indicated that older devices may require interim firmware updates if the currently installed firmware is older than the versions listed in the dependencies columns. For more information read the Product Release Notes or contact AMX Tech Support.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

10.0
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · high–critical · 9–10

v2.010highAV:N/AC:L/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 10 · Auswirkung 10
v3.09.8criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USAusnutzbarkeit 3.9 · Auswirkung 5.9
v2.010criticalAV:N/AC:L/Au:N/C:C/I:C/A:Csecondary · FSTEC (BDU) RU
v3.09.9criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:Hsecondary · CISA US
v3.09criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (63)

Betroffene Produkte und Versionsbereiche.

05

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-16-049-02AAMX Multiple Products Credential Management Vulnerabilities (Update A)2016-11-21icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

06

auch bekannt als (5)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2016-01-22geändert 2026-06-17
09

Referenzen (24)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan