CVE-2013-2796
mediumPriorität · verfolgen · 28EPSS 0.007 · 54. PerzentilEURUUSEPSS · bewertet 2026-10-27
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Behebungen
Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.
Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.
- MitigationCitectSCADAcisa_csaf_ot
Schneider Electric recommends that customers contact a support center: Vijeo Citect & CitectSCADA customers please contact the SCADA & MES Software Global Support Center located here: (http://www.citect.schneider-electric.com/contact-support), PowerLogic SCADA customers please contact your local country support organization at: (http://www.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page).
http://www.citect.schneider-electric.com/contact-support - MitigationPowerLogic SCADAcisa_csaf_ot
Schneider Electric recommends that customers contact a support center: Vijeo Citect & CitectSCADA customers please contact the SCADA & MES Software Global Support Center located here: (http://www.citect.schneider-electric.com/contact-support), PowerLogic SCADA customers please contact your local country support organization at: (http://www.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page).
http://www.citect.schneider-electric.com/contact-support - MitigationVijeo Citectcisa_csaf_ot
Schneider Electric recommends that customers contact a support center: Vijeo Citect & CitectSCADA customers please contact the SCADA & MES Software Global Support Center located here: (http://www.citect.schneider-electric.com/contact-support), PowerLogic SCADA customers please contact your local country support organization at: (http://www.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page).
http://www.citect.schneider-electric.com/contact-support
cvss
Technischer Schweregrad, 0–10. Eine Zeile je Quelle.
Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · medium–high · 5.9–8.4
schwächen
Die CWE-Schwächeklassen, zu denen dies gehört.
betroffene Produkte (16)
Betroffene Produkte und Versionsbereiche.
- schneider-electric powerlogic scada≤ 7.20nvdUScpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*
- schneider-electric powerlogic scada= 7.10nvdUScpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*
Advisories (1)
Hersteller- und Ökosystem-Meldungen dazu.
- ICSA-13-217-02Schneider Electric Vijeo Citect, CitectSCADA, PowerLogic SCADA Vulnerability2013-05-08icsa · cisa_csaf_otUS
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
auch bekannt als (4)
Weitere Namen und Kennungen dieser Entität.
quellen
Welche Quellen diesen Datensatz belegen und wann.
Referenzen (6)
Externe Belege — Patches, Meldungen, Analysen.
- http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02cnnvd
- http://www.citect.schneider-electric.com/cs-HF720SP459363cnnvd
- http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02enisa_euvd
- http://www.citect.schneider-electric.com/cs-HF720SP459363enisa_euvd
- http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02US Government Resourcenvd
- http://www.citect.schneider-electric.com/cs-HF720SP459363Patchnvd
Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.