Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Ein Hersteller-Fix ist verfügbar.

02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

8.6
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen⚠ Quellen uneinig · low–high · 2.8–8.6

v2.03.3lowAV:A/AC:L/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USAusnutzbarkeit 6.5 · Auswirkung 2.9
v2.02.8lowAV:A/AC:L/Au:N/C:N/I:N/A:P/E:Usecondary · CVSS-BT (t0sche)
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · CISA US
v3.18.6highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:Hsecondary · Siemens ProductCERT DE
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

betroffene Produkte (7)

Betroffene Produkte und Versionsbereiche.

05

Advisories (2)

Hersteller- und Ökosystem-Meldungen dazu.

  • SSA-783261SSA-783261: Denial of Service Vulnerability in Automation License Manager (ALM) Before V5.22012-12-12csaf · siemens_psirtDE

    A vulnerability was identified in the Automation License Manager software before V5.2 that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial of service preventing legitimate users from using the system. Siemens has released a new version for Automation License Manager and recommends to update to the latest version.

  • ICSA-12-349-01Siemens Automation License Manager Uncontrolled Resource Consumption2012-12-12icsa · cisa_csaf_otUS

    A vulnerability was identified in the Automation License Manager software before V5.2 that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial of service preventing legitimate users from using the system. Siemens has released a new version for Automation License Manager and recommends to update to the latest version.

06

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

07

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2012-12-18geändert 2026-06-16
09

Referenzen (8)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan