CVE-2012-2515

highPriorität · beachten · 57EPSS 0.276 · 98. PerzentilExploit · PoCEUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
27.6% (98th) EPSS
CVSS 9.3 · high
Is it mine?
23 products
Prüfe deine Angriffsfläche
Who says so?
4 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · bewertet 2026-10-27

Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.

01

Behebungen

Hersteller-Fix, Mitigation oder Workaround, wie von den Quellen veröffentlicht.

Noch kein Hersteller-Fix; eine Mitigation ist verfügbar.

  • MitigationProficy Batch Executioncisa_csaf_ot

    GE Intelligent Platforms recommends that the KeyHelp.ocx ActiveX control be unregistered and deleted to eliminate these vulnerabilities. GE Intelligent Platforms has recommended specific control removal instructions for each of the affected products to ensure it continues to function properly once the control is removed. Please see GE Security Advisory GEIP12-04 at the following location: (https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04)

    https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04
  • MitigationProficy HMI/SCADA – iFIXcisa_csaf_ot

    GE Intelligent Platforms recommends that the KeyHelp.ocx ActiveX control be unregistered and deleted to eliminate these vulnerabilities. GE Intelligent Platforms has recommended specific control removal instructions for each of the affected products to ensure it continues to function properly once the control is removed. Please see GE Security Advisory GEIP12-04 at the following location: (https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04)

    https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04
  • MitigationProficy Historiancisa_csaf_ot

    GE Intelligent Platforms recommends that the KeyHelp.ocx ActiveX control be unregistered and deleted to eliminate these vulnerabilities. GE Intelligent Platforms has recommended specific control removal instructions for each of the affected products to ensure it continues to function properly once the control is removed. Please see GE Security Advisory GEIP12-04 at the following location: (https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04)

    https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04
  • MitigationProficy Pulsecisa_csaf_ot

    GE Intelligent Platforms recommends that the KeyHelp.ocx ActiveX control be unregistered and deleted to eliminate these vulnerabilities. GE Intelligent Platforms has recommended specific control removal instructions for each of the affected products to ensure it continues to function properly once the control is removed. Please see GE Security Advisory GEIP12-04 at the following location: (https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04)

    https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04
  • MitigationSI7 I/O Drivercisa_csaf_ot

    GE Intelligent Platforms recommends that the KeyHelp.ocx ActiveX control be unregistered and deleted to eliminate these vulnerabilities. GE Intelligent Platforms has recommended specific control removal instructions for each of the affected products to ensure it continues to function properly once the control is removed. Please see GE Security Advisory GEIP12-04 at the following location: (https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04)

    https://ge-ip.force.com/communities/en_US/Article/GE-Intelligent-Platforms-Security-Advisory-GEIP12-04
02

cvss

Technischer Schweregrad, 0–10. Eine Zeile je Quelle.

9.3
010

Basiswert 0–10 · höher = schwerwiegender · Vektor überfahren zum Auflösen

v2.09.3highAV:N/AC:M/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USAusnutzbarkeit 8.6 · Auswirkung 10
v2.08.8highAV:N/AC:M/Au:N/C:C/I:C/A:C/E:Fsecondary · CVSS-BT (t0sche)
v3.08.8highCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
03

schwächen

Die CWE-Schwächeklassen, zu denen dies gehört.

04

Exploits (1)

Öffentlicher Proof-of-Concept- und Exploit-Code.

05

betroffene Produkte (23)

Betroffene Produkte und Versionsbereiche.

20 von 23 angezeigt
06

Advisories (1)

Hersteller- und Ökosystem-Meldungen dazu.

  • ICSA-12-131-02GE Intelligent Platforms Proficy HTML Help Vulnerabilities2012-02-11icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

07

auch bekannt als (3)

Weitere Namen und Kennungen dieser Entität.

08

quellen

Welche Quellen diesen Datensatz belegen und wann.

veröffentlicht 2012-07-05geändert 2026-06-16
10

Referenzen (25)

Externe Belege — Patches, Meldungen, Analysen.

scry

Angreifer nutzen Schwachstellen wie diese gegen im Internet exponierte Dienste aus. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan