Bender PSIRT (CSAF)
advisoryDEbender_psirt
Bender PSIRT CSAF 2.0 advisories (hosted by CERT@VDE).
01
Advisories (5)
Hersteller- und Ökosystem-Meldungen dazu.
02
Produkt-Aussagen (29)
Betroffene Produkte und Versionsbereiche.
- Customer&Partner 5.0.0<5.17.5
- Customer&Partner 5.17.5
- Firmware 4.2.0 installed on COM465ID
- Firmware 4.2.0 installed on COM465IP
- Firmware 4.2.0 installed on CP700
- Firmware 4.2.0 installed on CP907
- Firmware 4.2.0 installed on CP915
- Firmware 5.30.2<5.33.3 installed on CC612
- Firmware 5.30.2<5.33.3 installed on CC613
- Firmware 5.30.2<5.33.3 installed on ICC13xx
- Firmware 5.30.2<5.33.3 installed on ICC16xx
- Firmware 5.33.3 installed on CC612
- Firmware 5.33.3 installed on CC613
- Firmware 5.33.3 installed on ICC13xx
- Firmware 5.33.3 installed on ICC16xx
- Firmware <4.2.0 installed on COM465ID
- Firmware <4.2.0 installed on COM465IP
- Firmware <4.2.0 installed on CP700
- Firmware <4.2.0 installed on CP907
- Firmware <4.2.0 installed on CP915
20 von 29 angezeigt
03
CVE-Verknüpfungen (11)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2026-94410US | medium4.3OT erhöht | — | ||
A low privileged remote attacker is able to view a list of roles that should only be accessible to administrators. This results in a low level of confidentiality breach, as no part… | ||||
| CVE-2025-41708US | —OT erhöht | — | ||
Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive… | ||||
| CVE-2025-41682US | — | — | ||
An authenticated, low-privileged attacker can obtain credentials stored on the charge controller including the manufacturer password. | ||||
| CVE-2021-34602US | high8.8 | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields… | ||||
| CVE-2021-34601US | critical9.8OT erhöht | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh cred… | ||||
| CVE-2021-34591US | high7.8 | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip… | ||||
| CVE-2021-34590US | medium5.4 | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values ar… | ||||
| CVE-2021-34589US | high7.5 | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface. | ||||
| CVE-2021-34588US | high8.6 | — | ||
In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty… | ||||
| CVE-2021-34587US | medium5.3 | — | ||
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable. | ||||
| CVE-2019-19885US | critical9.1OT erhöht | — | ||
In Bender COMTRAXX, user authorization is validated for most, but not all, routes in the system. A user with knowledge about the routes can read and write configuration data withou… | ||||