cybersecurity@ch.abb.com
organization01
Rollen
Rollen dieser Identität.
02
Referenzen
Weitere Namen und Kennungen dieser Entität.
nvdUS cybersecurity@ch.abb.com
03
bewertete Schwachstellen (283)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2026-13599US | —OT erhöht | — | ||
Missing authentication for critical function vulnerability in ABB Ability Edgenius.
This issue affects Ability Edgenius: through 3.2.3.0. | ||||
| CVE-2026-17525US | — | — | ||
Incomplete cleanup vulnerability in ABB My Control System.
This issue affects My Control System: 26.4 and 26.5. | ||||
| CVE-2026-15953US | — | — | ||
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Protection and control IED manager (PCM600).
This issue affects Protection and… | ||||
| CVE-2026-15952US | — | — | ||
Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager (PCM600).
This issue affects Protection and control IED manager (PCM6… | ||||
| CVE-2026-19438US | — | — | ||
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Mint Workbench I.
This issue affects Mint Workbench I: through 5876. | ||||
| CVE-2023-5778US | — | — | ||
Improper handling of length parameter inconsistency vulnerability in ABB Freelance Controller DCP, ABB Freelance Controller AC700, ABB Freelance Controller AC800, and ABB Freelance… | ||||
| CVE-2026-79679US | — | — | ||
Use of Weak Credentials vulnerability in B&R Industrial Automation GmbH mapp Audit used in mapp Services.
This issue affects mapp Audit used in mapp Services: before 6.8.0. | ||||
| CVE-2026-12705US | — | — | ||
Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).
This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update To… | ||||
| CVE-2026-6901US | — | — | ||
Untrusted Search Path vulnerability in B&R Industrial Automation GmbH APROL.
This issue affects APROL: before R 4.4-01P5. | ||||
| CVE-2026-6900US | — | — | ||
Improper certificate validation vulnerability in B&R Industrial Automation GmbH APROL.
This issue affects APROL: before R 4.4-01P5. | ||||
| CVE-2025-13162US | — | — | ||
Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master.
This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master:… | ||||
| CVE-2025-7064US | — | — | ||
Authentication bypass by primary weakness vulnerability in ABB Freelance.
This issue affects Freelance: through 2013, 2013 SP1, 2016, 2016 SP1, 2019, 2019 SP1, 2019 SP1 FP1, 2024. | ||||
| CVE-2025-14774US | —OT erhöht | — | ||
Incorrect Authorization vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14773US | medium5.4 | — | ||
Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14772US | — | — | ||
Authorization bypass through User-Controlled key vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-14771US | — | — | ||
Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.
This issue affects T-MAC Plus: 4.0-24. | ||||
| CVE-2025-11482US | — | — | ||
An Allocation of Resources Without Limits or Throttling vulnerability in the OPC-UA Server used in PPT30
Operating System versions before 1.8.0 may be used by an unauthenticated n… | ||||
| CVE-2025-3756US | — | — | ||
A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC… | ||||
| CVE-2025-13779US | —OT erhöht | — | ||
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. | ||||
| CVE-2025-13778US | —OT erhöht | — | ||
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. | ||||