Texas Instruments Bluetooth Low Energy Denial of Service and Remote Code Execution Vulnerability
On November 1st, 2018, Armis announced the presence of a Remote Code Execution (RCE) or Denial of Service (DoS) vulnerability in the Bluetooth Low Energy (BLE) Stack on Texas Instruments (TI) chips CC2640 and CC2650. This vulnerability has been assigned the Common Vulnerabilities and Exposures (CVE) ID of CVE-2018-16986. The vulnerability is due to a memory corruption condition that may occur when processing malformed BLE frames. An attacker in close proximity to an affected device that is actively scanning could exploit the issue by broadcasting malformed BLE frames. A successful exploit may result in the attacker gaining the ability to execute arbitrary code or cause a denial of service condition on an affected device. There are no workarounds that address this vulnerability. This advisory is available at the following link: https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap ["https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20181101-ap"]
beschreibt (1)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2018-16986US | high8.8 | — | ||
Texas Instruments BLE-STACK v2.2.1 for SimpleLink CC2640 and CC2650 devices allows remote attackers to execute arbitrary code via a malformed packet that triggers a buffer overflow… | ||||
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
Behebungen (1)
- BehobenCisco Aironet Access Point Software
Cisco has released software updates that address this vulnerability.
https://software.cisco.com
Advisories wie diese benennen die exponierten Produkte, die Angreifer auf Ihrer Angriffsfläche ins Visier nehmen. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan