SSA-864900

csafDEsiemens_psirt

SSA-864900: Multiple Vulnerabilities in Fortigate NGFW before V7.6.6 on RUGGEDCOM APE1808 Devices

Advisory ansehen veröffentlicht 2025-05-13

Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.

01

beschreibt (29)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2026-84392US——
A NULL Pointer Dereference vulnerability [CWE-476] vulnerability in Fortinet FortiOS 7.4 all versions, FortiOS 7.2 all versions, FortiPAM 1.9.0, FortiPAM 1.8 all versions, FortiPAM…
CVE-2026-59840US——
A buffer over-read vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions,…
CVE-2026-59837US——
A stack-based buffer overflow vulnerability in Fortinet FortiOS 7.4.0 through 7.4.1, FortiOS 7.2 all versions, FortiPAM 1.8.0 through 1.8.2, FortiPAM 1.7 all versions, FortiPAM 1.6…
CVE-2025-62826USmedium4.3—
An Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability [CWE-113] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4…
CVE-2025-62675USmedium4.3—
An Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability [CWE-113] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.4, FortiOS 7.4…
CVE-2025-43892US——
A buffer over-read vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions…
CVE-2025-67862US——
An Internal Asset Exposed to Unsafe Debug Access Level or State vulnerability [CWE-1244] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.2, FortiOS 7.4.0 through 7.4.7, FortiOS…
CVE-2025-53844US——
A out-of-bounds write vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11 allows attacker to execute unauthorized code…
CVE-2025-25249UScritical9.8OT kritischKEV
A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS…
CVE-2025-59719US—OT kritisch—
An improper verification of cryptographic signature vulnerability in Fortinet FortiWeb 8.0.0, FortiWeb 7.6.0 through 7.6.4, FortiWeb 7.4.0 through 7.4.9 may allow an unauthenticate…
CVE-2025-59718US—OT kritischKEV
A improper verification of cryptographic signature vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 t…
CVE-2025-58413US——
A stack-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 al…
CVE-2025-54821USmedium6.0—
An Improper Privilege Management vulnerability [CWE-269] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.11, FortiOS 7.2 all versions, FortiOS 7.0…
CVE-2025-53843US——
A stack-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 al…
CVE-2025-58903USmedium4.9—
An Unchecked Return Value vulnerability [CWE-252] in Fortinet FortiOS version 7.6.0 through 7.6.3 and before 7.4.8 API allows an authenticated user to cause a Null Pointer Derefer…
CVE-2025-57740UShigh8.8—
An Heap-based Buffer Overflow vulnerability [CWE-122] in FortiOS version 7.6.2 and below, version 7.4.7 and below, version 7.2.10 and below, 7.0 all versions, 6.4 all versions; For…
CVE-2025-47890USmedium6.1—
An URL Redirection to Untrusted Site vulnerabilities [CWE-601] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS…
CVE-2025-31514USmedium4.3—
A insertion of sensitive information into log file vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4 all versions, FortiOS 7.2 all versions, FortiOS 7.0 all versio…
CVE-2025-31366USmedium6.1—
An Improper Neutralization of Input During Web Page Generation vulnerability [CWE-79] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.…
CVE-2025-25253US——
An Improper Validation of Certificate with Host Mismatch vulnerability [CWE-297] in FortiProxy version 7.6.1 and below, version 7.4.8 and below, 7.2 all versions, 7.0 all versions…
20 von 29 angezeigt
02

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

03

Behebungen (35)

  • MitigationRUGGEDCOM APE1808

    Disable security fabric access into interface. Only allow legit devices in Wifi Controller > Managed FortiAPs (see https://fortiguard.fortinet.com/psirt/FG-IR-25-358 for more information)

  • MitigationRUGGEDCOM APE1808

    Disable security fabric access into interface. Only allow legit devices in Wifi Controller > Managed FortiAPs. Remove inter-controller-peer elements in config wireless-controller inter-controller configuration. (see https://fortiguard.fortinet.com/psirt/FG-IR-25-632 for more information)

  • MitigationRUGGEDCOM APE1808

    For each interface, remove "fabric" access (see https://fortiguard.fortinet.com/psirt/FG-IR-25-084)

  • MitigationRUGGEDCOM APE1808

    To prevent being affected by this vulnerability on vulnerable versions, please turn off the FortiCloud login feature (if enabled, disabled by default) temporarily until upgrading to a non-affected version. (see https://fortiguard.fortinet.com/psirt/FG-IR-25-647 for more information)

  • MitigationRUGGEDCOM APE1808

    To prevent being affected by this vulnerability on vulnerable versions, please turn off the FortiCloud login feature (if enabled, disabled by default) temporarily until upgrading to a non-affected version. (see https://fortiguard.fortinet.com/psirt/FG-IR-25-647 for more information)

  • MitigationRUGGEDCOM APE1808

    Under the config vpn ipsec phase1-interface configuration, either set authmethod to psk, or set digital-signature-auth to disable (see https://fortiguard.fortinet.com/psirt/FG-IR-24-373)

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

  • BehobenRUGGEDCOM APE1808

    Update Fortigate NGFW to V7.6.6 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

scry

Advisories wie diese benennen die exponierten Produkte, die Angreifer auf Ihrer Angriffsfläche ins Visier nehmen. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.

Kostenloser Scan