PPSA-2025-002

csafDEpilz_psirt

Pilz: Missing Authentication in Node-RED integration

Advisory ansehen veröffentlicht 2025-07-01

Authentication is not configured by default for the Node-RED server on the Pilz industrial PC IndustrialPI. An unauthenticated remote attacker has full access to the Node-RED server and can run arbitrary operating system commands on the underlying operating system with privileged rights.

01

beschreibt (1)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2025-41656US—OT erhöhtExploit
An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by d…
02

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

03

Behebungen (2)

  • MitigationFirmware Bullseye <=2024-08 installed on IndustrialPI 4

    Limit network access to the IndustrialPI by using a firewall or similar measures.

  • BehobenFirmware Bullseye <=2024-08 installed on IndustrialPI 4

    Consult our PDF with remediations which you can find under [www.pilz.com/downloads](https://www.pilz.com/search#currentPage=1&SEARCH=Security%20Advis.%20IndustrialPI%20Remediat.). In order to activate the authentication as described in the PDF, you have to have the Node-RED service enabled via the web application.