sca-2026-0010

csafDEsick_psirt

AppEngine vulnerability affects SICK ICR890-4 and SICK InspectorP6xx devices

Advisory ansehen veröffentlicht 2026-08-24

Multiple internal virtual filesystem paths are unintentionally accessible remotely in the SICK ICR890-4 and SICK InspectorP6xx devices. If exploited, this vulnerability could potentially allow an unauthenticated attacker to compromise the availability, integrity, and confidentiality of the devices.

01

beschreibt (1)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2026-11841US——
An attacker may perform unauthenticated read and write operations on sensitive filesystem areas via the AppEngine Fileaccess over HTTP due to improper access restrictions. A critic…
02

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

03

Behebungen (6)

  • MitigationSICK InspectorP63x all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK InspectorP64x all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • MitigationSICK InspectorP65x all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources ”SICK Operating Guidelines” and ”ICS-CERT recommended practices on Industrial Security” could help to implement the general security practices.

  • BehobenSICK ICR890-4 with firmware < 2.15.0

    Users are recommended to upgrade to version 2.15.0.

  • BehobenSICK InspectorP61x with firmware < 5.4.0

    Users are recommended to upgrade to version 5.4.0.

  • BehobenSICK InspectorP62x with firmware < 5.4.0

    Users are recommended to upgrade to version 5.4.0.