DeutschIn der Originalsprache angezeigt — eine vollständige Übersetzung ist für eine zukünftige Version geplant.
Broadcom Brocade SANnav: Mehrere Schwachstellen
Advisory ansehen veröffentlicht 2026-09-22
Ein Angreifer kann mehrere Schwachstellen in Broadcom Brocade SANnav ausnutzen, um Administratorrechte zu erlangen, Sicherheitsmaßnahmen zu umgehen, beliebigen Code auszuführen, Daten zu manipulieren oder vertrauliche Informationen offenzulegen.
01
beschreibt (8)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2026-14443US | — | — | ||
Incomplete log sanitization during bulk IPsec policy collection in Brocade SANnav versions before 3.0.1a permit extension switch pre-shared keys to be written to system logs. Indiv… | ||||
| CVE-2026-14442US | — | — | ||
An information exposure vulnerability in the job scheduling component of SANnav allows sensitive credentials to be written to application logs in plain text. When scheduled support… | ||||
| CVE-2026-14441US | — | — | ||
A logic flaw in Java cache key handling object comparison handling could lead to improper identifier resolution when processing specific user account structures. The issue has been… | ||||
| CVE-2026-82372US | — | — | ||
Improper handling of sensitive data during IPsec policy creation and modification in Brocade SANnav versions before 3.0.1a results in pre-shared keys being recorded in application… | ||||
| CVE-2026-82371US | — | — | ||
Plaintext exposure of sensitive authentication data in Brocade SANnav discovery service log files enables individuals with file read access to retrieve administrative switch creden… | ||||
| CVE-2026-82370US | — | — | ||
Unauthenticated remote command injection in the Brocade SANnav orchestrator HTTP service permits network-adjacent attackers to execute arbitrary administrative switch CLI commands… | ||||
| CVE-2026-82369US | — | — | ||
Insufficient input sanitization of shell metacharacters in the Brocade SANnav CLI scripting component permits authenticated users to break out of restricted execution contexts on m… | ||||
| CVE-2026-82368US | — | — | ||
Insecure access controls on internal service ports in Brocade SANnav versions before 3.0.1a allow local, non-administrative host users to communicate directly with backend manageme… | ||||
02
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
- Brocade Security Advisory vom 2026-09-22external
scry
Advisories wie diese benennen die exponierten Produkte, die Angreifer auf Ihrer Angriffsfläche ins Visier nehmen. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.
Kostenloser Scan