Siemens Industrial Products glibc Library Vulnerability (Update C)
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
beschreibt (1)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2015-7547US | high8.1 | Exploit | ||
Multiple stack-based buffer overflows in the (1) send_dg and (2) send_vc functions in the libresolv library in the GNU C Library (aka glibc or libc6) before 2.23 allow remote attac… | ||||
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
- ICS Advisory ICSA-16-103-01C JSONself
- Recommended Practicesexternal
- ICS Advisory ICSA-16-103-01C - Web Versionself
- Recommended Practicesexternal
- Recommended Practicesexternal
- Recommended Practicesexternal
- Recommended Practicesexternal
- Recommended Practicesexternal
Behebungen (5)
- MitigationAPE (Linux)
As a general security measure, Siemens strongly recommends to protect network access to nonperimeter devices with appropriate mechanisms. It is advised to configure the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.
- MitigationBasic RT V13
As a general security measure, Siemens strongly recommends to protect network access to nonperimeter devices with appropriate mechanisms. It is advised to configure the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.
- MitigationROX II
As a general security measure, Siemens strongly recommends to protect network access to nonperimeter devices with appropriate mechanisms. It is advised to configure the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.
- MitigationSCALANCE M-800/S615
As a general security measure, Siemens strongly recommends to protect network access to nonperimeter devices with appropriate mechanisms. It is advised to configure the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.
- MitigationSINEMA Remote Connect
As a general security measure, Siemens strongly recommends to protect network access to nonperimeter devices with appropriate mechanisms. It is advised to configure the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.