ICSA-23-080-02

icsaUScisa_csaf_ot

Delta Electronics InfraSuite Device Master

Advisory ansehen veröffentlicht 2023-03-29

Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to obtain access to files and credentials, escalate privileges, and remotely execute arbitrary code.

01

beschreibt (13)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2023-1145UShigh7.8—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allo…
CVE-2023-1144UShigh8.8OT erhöht—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and byp…
CVE-2023-1143UShigh8.8—
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.
CVE-2023-1142UScritical9.8—
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting…
CVE-2023-1141UShigh8.8—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could…
CVE-2023-1140UScritical9.8OT erhöht—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the cont…
CVE-2023-1139UShigh8.8—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deseriali…
CVE-2023-1138UShigh7.5—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration…
CVE-2023-1137UShigh8.8—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator…
CVE-2023-1136UShigh7.5OT erhöht—
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.
CVE-2023-1135UShigh7.8—
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local p…
CVE-2023-1134UShigh8.8—
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plain…
CVE-2023-1133UScritical9.8Exploit
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service acc…