Siemens UMC Stack (Update H)
The products listed below contain two security vulnerabilities in the UMC component that could allow an attacker to cause a partial denial- of-service of the UMC component, or to locally escalate privileges from a user with administrative privileges to execute code with SYSTEM level privileges. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
beschreibt (3)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2020-7588US | medium5.3 | — | ||
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versi… | ||||
| CVE-2020-7587US | high8.2 | — | ||
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versi… | ||||
| CVE-2020-7581US | medium6.7 | — | ||
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versi… | ||||
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
- SSA-841348: Multiple Vulnerabilities in the UMC Component - CSAF Versionself
- SSA-841348: Multiple Vulnerabilities in the UMC Component - PDF Versionself
- SSA-841348: Multiple Vulnerabilities in the UMC Component - TXT Versionself
- ICS Advisory ICSA-20-196-05 JSONself
- Recommended Practicesexternal
- ICS Advisory ICSA-20-196-05 - Web Versionself
- Recommended Practicesexternal
- Recommended Practicesexternal
Behebungen (92)
- MitigationOpcenter Execution Discrete
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter Execution Discrete
Have the software running on systems within trusted networks
- MitigationOpcenter Execution Discrete
Have the software running on systems within trusted networks
- MitigationOpcenter Execution Foundation
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter Execution Foundation
Have the software running on systems within trusted networks
- MitigationOpcenter Execution Foundation
Have the software running on systems within trusted networks
- MitigationOpcenter Execution Process
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter Execution Process
Have the software running on systems within trusted networks
- MitigationOpcenter Execution Process
Have the software running on systems within trusted networks
- MitigationOpcenter Intelligence
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter Intelligence
Have the software running on systems within trusted networks
- MitigationOpcenter Intelligence
Have the software running on systems within trusted networks
- MitigationOpcenter Quality
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter Quality
Have the software running on systems within trusted networks
- MitigationOpcenter Quality
Have the software running on systems within trusted networks
- MitigationOpcenter RD&L
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationOpcenter RD&L
Have the software running on systems within trusted networks
- MitigationOpcenter RD&L
Have the software running on systems within trusted networks
- MitigationSIMATIC IT LMS
Have the software running on systems within trusted networks
- MitigationSIMATIC IT LMS
Have the software running on systems within trusted networks
- MitigationSIMATIC IT Production Suite
Have the software running on systems within trusted networks
- MitigationSIMATIC IT Production Suite
Have the software running on systems within trusted networks
- MitigationSIMATIC Notifier Server for Windows
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMATIC Notifier Server for Windows
Have the software running on systems within trusted networks
- MitigationSIMATIC Notifier Server for Windows
Have the software running on systems within trusted networks
- MitigationSIMATIC PCS neo
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMATIC PCS neo
Have the software running on systems within trusted networks
- MitigationSIMATIC PCS neo
Have the software running on systems within trusted networks
- MitigationSIMATIC STEP 7 (TIA Portal) V15
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMATIC STEP 7 (TIA Portal) V15
Have the software running on systems within trusted networks
- MitigationSIMATIC STEP 7 (TIA Portal) V15
Have the software running on systems within trusted networks
- MitigationSIMATIC STEP 7 (TIA Portal) V16
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMATIC STEP 7 (TIA Portal) V16
Have the software running on systems within trusted networks
- MitigationSIMATIC STEP 7 (TIA Portal) V16
Have the software running on systems within trusted networks
- MitigationSIMOCODE ES V15.1
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMOCODE ES V15.1
Have the software running on systems within trusted networks
- MitigationSIMOCODE ES V15.1
Have the software running on systems within trusted networks
- MitigationSIMOCODE ES V16
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSIMOCODE ES V16
Have the software running on systems within trusted networks
- MitigationSIMOCODE ES V16
Have the software running on systems within trusted networks
- MitigationSoft Starter ES V15.1
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSoft Starter ES V15.1
Have the software running on systems within trusted networks
- MitigationSoft Starter ES V15.1
Have the software running on systems within trusted networks
- MitigationSoft Starter ES V16
CVE-2020-7581: Make sure that there is no executable at the following locations: C:\Program.exe, C:\Program Files\Common.exe, or C:\Program Files\Common Files\Siemens\Automation\Simatic.exe
- MitigationSoft Starter ES V16
Have the software running on systems within trusted networks
- MitigationSoft Starter ES V16
Have the software running on systems within trusted networks
- Kein Fix geplantSIMATIC Notifier Server for Windows
Currently no fix is planned
- Kein Fix geplantSIMATIC Notifier Server for Windows
Currently no fix is planned
- Kein Fix geplantSIMATIC Notifier Server for Windows
Currently no fix is planned
- BehobenOpcenter Execution Discrete
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Discrete
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Discrete
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Foundation
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Foundation
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Foundation
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Process
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Process
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Execution Process
Update to V3.2 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Intelligence
Update to V3.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Intelligence
Update to V3.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Intelligence
Update to V3.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Quality
Update to V11.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Quality
Update to V11.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter Quality
Update to V11.3 or later version
https://support.sw.siemens.com/ - BehobenOpcenter RD&L
Update to V8.1 or later version
https://support.sw.siemens.com/ - BehobenOpcenter RD&L
Update to V8.1 or later version
https://support.sw.siemens.com/ - BehobenOpcenter RD&L
Update to V8.1 or later version
https://support.sw.siemens.com/ - BehobenSIMATIC IT LMS
Update to V2.6 or later version
https://support.sw.siemens.com/ - BehobenSIMATIC IT LMS
Update to V2.6 or later version
https://support.sw.siemens.com/ - BehobenSIMATIC IT Production Suite
Update to V8.0 or later version
https://support.sw.siemens.com/ - BehobenSIMATIC IT Production Suite
Update to V8.0 or later version
https://support.sw.siemens.com/ - BehobenSIMATIC PCS neo
Update to V3.0 SP1 or later version. To obtain SIMATIC PCS neo contact your local support.
- BehobenSIMATIC PCS neo
Update to V3.0 SP1 or later version. To obtain SIMATIC PCS neo contact your local support.
- BehobenSIMATIC PCS neo
Update to V3.0 SP1 or later version. To obtain SIMATIC PCS neo contact your local support.
- BehobenSIMATIC STEP 7 (TIA Portal) V15
Update to V15.1 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC STEP 7 (TIA Portal) V15
Update to V15.1 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC STEP 7 (TIA Portal) V15
Update to V15.1 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - BehobenSIMATIC STEP 7 (TIA Portal) V16
Update to V16 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC STEP 7 (TIA Portal) V16
Update to V16 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMATIC STEP 7 (TIA Portal) V16
Update to V16 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - BehobenSIMOCODE ES V15.1
Update to V15 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109768994/ - BehobenSIMOCODE ES V15.1
Update to V15 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109768994/ - BehobenSIMOCODE ES V15.1
Update to V15 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109768994/ - BehobenSIMOCODE ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109781888/ - BehobenSIMOCODE ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109781888/ - BehobenSIMOCODE ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109781888/ - BehobenSoft Starter ES V15.1
Update to V15 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109769017/ - BehobenSoft Starter ES V15.1
Update to V15 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109769017/ - BehobenSoft Starter ES V15.1
Update to V15 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109769017/ - BehobenSoft Starter ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109771657/ - BehobenSoft Starter ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109771657/ - BehobenSoft Starter ES V16
Update to V16 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109771657/