ICSMA-20-261-01

icsaUScisa_csaf_ot

ICSMA-20-261-01_Philips Clinical Collaboration Platform

Advisory ansehen veröffentlicht 2020-09-17

Northridge Hospital Medical Center reported these vulnerabilities to Philips.

01

beschreibt (5)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2020-16247UShigh7.1—
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the…
CVE-2020-16200USmedium6.5—
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker…
CVE-2020-16198USmedium6.3—
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correc…
CVE-2020-14525USlow3.5—
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a…
CVE-2020-14506USmedium4.3—
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the pro…
02

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

03

Behebungen (5)

  • MitigationClinical Collaboration Platform

    Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.

  • MitigationClinical Collaboration Platform

    Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.

  • MitigationClinical Collaboration Platform

    Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.

  • MitigationClinical Collaboration Platform

    Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.

  • MitigationClinical Collaboration Platform

    Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.