ICSMA-20-261-01_Philips Clinical Collaboration Platform
Northridge Hospital Medical Center reported these vulnerabilities to Philips.
beschreibt (5)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2020-16247US | high7.1 | — | ||
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the… | ||||
| CVE-2020-16200US | medium6.5 | — | ||
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited
resource, thereby enabling an attacker… | ||||
| CVE-2020-16198US | medium6.3 | — | ||
When an attacker claims to have a given identity,
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not prove or insufficiently proves the claim is correc… | ||||
| CVE-2020-14525US | low3.5 | — | ||
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input
before it is placed in output used as a… | ||||
| CVE-2020-14506US | medium4.3 | — | ||
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the pro… | ||||
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
Behebungen (5)
- MitigationClinical Collaboration Platform
Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.
- MitigationClinical Collaboration Platform
Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.
- MitigationClinical Collaboration Platform
Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.
- MitigationClinical Collaboration Platform
Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.
- MitigationClinical Collaboration Platform
Philips Clinical Collaboration Platform Version 12.2.5 was released in May 2020 to remediate CWE-16, CWE-352, CWE-83, and CWE-693. Philips requires manual intervention to remediate CWE-757.