ICSA-20-170-05

icsaUScisa_csaf_ot

Rockwell Automation FactoryTalk View SE

Advisory ansehen veröffentlicht 2020-06-18

Successful exploitation of these vulnerabilities may allow a remote authenticated attacker to manipulate data of affected devices.

01

beschreibt (4)

Zugehörige CVEs.

IDSchweregrad ausnutzbar
CVE-2020-12031UShigh7.8—
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memor…
CVE-2020-12028UShigh8.1OT hochExploit
In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handl…
CVE-2020-12027USmedium4.3Exploit
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this informa…
CVE-2020-12029UShigh7.8Exploit
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file…
02

Referenzen

Externe Belege — Patches, Meldungen, Analysen.

03

Behebungen (6)

  • MitigationFactoryTalk View SE

    For CVE-2020-12029 Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 - Patch Roll-up for CPR9 SRx.

  • MitigationFactoryTalk View SE

    For CVE-2020-12031 Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 - Patch Roll-up for CPR9 SRx.

  • MitigationFactoryTalk View SE

    Rockwell Automation has released new versions of the affected products to mitigate the reported vulnerabilities. Affected users who are not able to apply the latest update are encouraged to seek additional mitigations or workarounds from the vendor's published guidelines in their security advisory.

    https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944
  • MitigationFactoryTalk View SE

    Rockwell Automation has released new versions of the affected products to mitigate the reported vulnerabilities. Affected users who are not able to apply the latest update are encouraged to seek additional mitigations or workarounds from the vendor's published guidelines in their security advisory.

    https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1126944
  • BehobenFactoryTalk View SE

    For CVE-2020-12028 and CVE-2020-12027 Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.

  • BehobenFactoryTalk View SE

    For CVE-2020-12028 and CVE-2020-12027 Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.