ICSMA-17-215-02_Siemens Molecular Imaging Vulnerabilities
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
beschreibt (4)
Zugehörige CVEs.
| ID | Schweregrad | ausnutzbar | ||
|---|---|---|---|---|
| CVE-2015-7861US | high10.0 | — | ||
Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute arbitrary code by sending unspecified command… | ||||
| CVE-2015-7860US | high10.0 | — | ||
Stack-based buffer overflow in the agent in Persistent Accelerite Radia Client Automation (formerly HP Client Automation), possibly before 9.1, allows remote attackers to execute a… | ||||
| CVE-2015-1635US | high10.0OT kritisch | KEV | ||
HTTP.sys in Microsoft Windows 7 SP1, Windows Server 2008 R2 SP1, Windows 8, Windows 8.1, and Windows Server 2012 Gold and R2 allows remote attackers to execute arbitrary code via c… | ||||
| CVE-2015-1497US | high10.0 | Exploit | ||
radexecd.exe in Persistent Systems Radia Client Automation (RCA) 7.9, 8.1, 9.0, and 9.1 allows remote attackers to execute arbitrary commands via a crafted request to TCP port 3465… | ||||
Referenzen
Externe Belege — Patches, Meldungen, Analysen.
Behebungen (16)
- MitigationSiemens PET/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens PET/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens PET/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens PET/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Workplaces/Symbia.net Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Workplaces/Symbia.net Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Workplaces/Symbia.net Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT Workplaces/Symbia.net Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT/CT Systems Windows 7-Based
In addition, Siemens recommends:
- MitigationSiemens SPECT/CT Systems Windows 7-Based
In addition, Siemens recommends:
Advisories wie diese benennen die exponierten Produkte, die Angreifer auf Ihrer Angriffsfläche ins Visier nehmen. Sehen Sie mit einem kostenlosen Passiv-Scan, was exponiert ist.