SSA-282044: DLL Hijacking Vulnerability in Siemens Web Installer used by the Online Software Delivery
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the affected applications downloaded e.g. via OSD (Online Software Delivery). Siemens has released new versions for several affected products and recommends using the latest versions during setup and installation. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
describes (1)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2025-30033US | — | — | ||
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the aff… | ||||
references
External citations — patches, advisories, analysis.
remediations (278)
- MitigationAutomation License Manager V6.0
Harden the application host to prevent local access by untrusted personnel
- MitigationAutomation License Manager V6.2
Harden the application host to prevent local access by untrusted personnel
- MitigationCEMAT V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationCP PtP Param configuring interface
Harden the application host to prevent local access by untrusted personnel
- MitigationCreate MyConfig (CMC)
Harden the application host to prevent local access by untrusted personnel
- MitigationEnergy Support Library (EnSL)
Harden the application host to prevent local access by untrusted personnel
- MitigationFM Configuration Package
Harden the application host to prevent local access by untrusted personnel
- MitigationModular PID CTRL Tool
Harden the application host to prevent local access by untrusted personnel
- MitigationMultiFieldbus Configuration Tool (MFCT)
Harden the application host to prevent local access by untrusted personnel
- MitigationOpenPCS 7 V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationOpenPCS 7 V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Automation Tool
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Automation Tool SDK Windows
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC BATCH V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC BATCH V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Control Function Library (CFL) V1.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Control Function Library (CFL) V2.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Control Function Library (CFL) V3.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Control Function Library (CFL) V4.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Energy Suite V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Energy Suite V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Energy Suite V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Logon V1.6
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Logon V2.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP CREATOR V3.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP CREATOR V4.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP CREATOR V2.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP CREATOR V5.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP Integrator V1.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC MTP Integrator V2.x
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Management Agent
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Management Console
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC NET PC Software V16
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC NET PC Software V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC NET PC Software V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC NET PC Software V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC NET PC Software V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC ODK 1500S
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Faceplates V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Functions V2.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Functions V2.2
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Graphics V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Graphics V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Library V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Basis Faceplates V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Basis Library V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Basis Library V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Industry Library V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Industry Library V9.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Industry Library V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Logic Matrix V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Logic Matrix V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 MPC Configurator
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 PowerControl V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Standard Chemical Library V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 Standard Chemical Library V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 TeleControl V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7/OPEN OS V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS neo V5.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS neo V6.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PDM Maintenance Station V5.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PDM V9.2
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC PDM V9.3
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC ProSave V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC ProSave V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC ProSave V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC ProSave V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Process Function Library (PFL) V4.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Process Historian 2020
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Process Historian 2022
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Process Historian 2024
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Route Control V10.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Route Control V9.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7 F Systems V6.3
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7 F Systems V6.4
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-1500 Software Controller V2
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-1500 Software Controller V3
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-Fail-safe Configuration Tool (S7-FCT)
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PCT
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PLCSIM Advanced
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PLCSIM V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PLCSIM V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PLCSIM V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC S7-PLCSIM V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC STEP 7 CFC V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC STEP 7 CFC V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC STEP 7 V5.7
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Safety Matrix V6.3
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC Target
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Runtime Advanced
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Runtime Professional
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Runtime Professional V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC TeleControl
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Unified Line Coordination
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Unified PC Runtime V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Unified PC Runtime V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Unified PC Runtime V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Unified Sequence
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V7.5
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V8.0
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V8.1
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Visualization Architect (SiVArc) V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Visualization Architect (SiVArc) V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Visualization Architect (SiVArc) V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC Visualization Architect (SiVArc) V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC flexible ES
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC eaSie Core Package (6DL5424-0AX00-0AV8)
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC eaSie Document Skills
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8)
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC eaSie Workflow Skills
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMATIC D7-SYS
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMIT Rapid Tester
Harden the application host to prevent local access by untrusted personnel
- MitigationSIMIT Simulation Platform
Harden the application host to prevent local access by untrusted personnel
- MitigationSINAMICS Startdrive V17
Harden the application host to prevent local access by untrusted personnel
- MitigationSINAMICS Startdrive V18
Harden the application host to prevent local access by untrusted personnel
- MitigationSINAMICS Startdrive V19
Harden the application host to prevent local access by untrusted personnel
- MitigationSINAMICS Startdrive V20
Harden the application host to prevent local access by untrusted personnel
- MitigationSINEC NMS
Harden the application host to prevent local access by untrusted personnel
- MitigationSINEMA Remote Connect Client
Harden the application host to prevent local access by untrusted personnel
- MitigationSITRANS
Harden the application host to prevent local access by untrusted personnel
- MitigationSiemens Network Planner (SINETPLAN)
Harden the application host to prevent local access by untrusted personnel
- MitigationStandard PID CTRL Tool
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Administrator
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Portal Cloud Connector
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Portal Test Suite V17
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Portal Test Suite V18
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Portal Test Suite V19
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Portal Test Suite V20
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Project-Server
Harden the application host to prevent local access by untrusted personnel
- MitigationTIA Project-Server V17
Harden the application host to prevent local access by untrusted personnel
- MitigationTeleControl Server Basic V3.1
Harden the application host to prevent local access by untrusted personnel
- MitigationTotally Integrated Automation Portal (TIA Portal) V17
Harden the application host to prevent local access by untrusted personnel
- MitigationTotally Integrated Automation Portal (TIA Portal) V18
Harden the application host to prevent local access by untrusted personnel
- MitigationTotally Integrated Automation Portal (TIA Portal) V19
Harden the application host to prevent local access by untrusted personnel
- MitigationTotally Integrated Automation Portal (TIA Portal) V20
Harden the application host to prevent local access by untrusted personnel
- MitigationWinCC Panel Image Setup
Harden the application host to prevent local access by untrusted personnel
- No fix plannedAutomation License Manager V6.0
Currently no fix is planned
- No fix plannedCEMAT V10.0
Currently no fix is planned
- No fix plannedEnergy Support Library (EnSL)
Currently no fix is planned
- No fix plannedOpenPCS 7 V10.0
Currently no fix is planned
- No fix plannedOpenPCS 7 V9.1
Currently no fix is planned
- No fix plannedSIMATIC BATCH V10.0
Currently no fix is planned
- No fix plannedSIMATIC BATCH V9.1
Currently no fix is planned
- No fix plannedSIMATIC Control Function Library (CFL) V1.x
Currently no fix is planned
- No fix plannedSIMATIC Control Function Library (CFL) V2.x
Currently no fix is planned
- No fix plannedSIMATIC Logon V1.6
Currently no fix is planned
- No fix plannedSIMATIC MTP CREATOR V3.x
Currently no fix is planned
- No fix plannedSIMATIC ODK 1500S
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Advanced Process Functions V2.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Advanced Process Functions V2.2
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Advanced Process Graphics V10.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Advanced Process Graphics V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Industry Library V10.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Industry Library V9.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Industry Library V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Logic Matrix V10.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 PowerControl V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Standard Chemical Library V10.0
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 Standard Chemical Library V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7 TeleControl V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS 7/OPEN OS V9.1
Currently no fix is planned
- No fix plannedSIMATIC PCS neo V5.0
Currently no fix is planned
- No fix plannedSIMATIC PDM Maintenance Station V5.0
Currently no fix is planned
- No fix plannedSIMATIC PDM V9.2
Currently no fix is planned
- No fix plannedSIMATIC ProSave V18
Currently no fix is planned
- No fix plannedSIMATIC Process Function Library (PFL) V4.0
Currently no fix is planned
- No fix plannedSIMATIC Process Historian 2020
Currently no fix is planned
- No fix plannedSIMATIC Process Historian 2022
Currently no fix is planned
- No fix plannedSIMATIC S7 F Systems V6.3
Currently no fix is planned
- No fix plannedSIMATIC S7 F Systems V6.4
Currently no fix is planned
- No fix plannedSIMATIC S7-1500 Software Controller V2
Currently no fix is planned
- No fix plannedSIMATIC S7-PLCSIM V17
Currently no fix is planned
- No fix plannedSIMATIC S7-PLCSIM V18
Currently no fix is planned
- No fix plannedSIMATIC S7-PLCSIM V19
Currently no fix is planned
- No fix plannedSIMATIC STEP 7 CFC V19
Currently no fix is planned
- No fix plannedSIMATIC STEP 7 CFC V20
Currently no fix is planned
- No fix plannedSIMATIC Safety Matrix V6.3
Currently no fix is planned
- No fix plannedSIMATIC WinCC flexible ES
Currently no fix is planned
- No fix plannedTIA Portal Test Suite V17
Currently no fix is planned
- No fix plannedTIA Portal Test Suite V18
Currently no fix is planned
- No fix plannedTIA Project-Server V17
Currently no fix is planned
- No fix availableCP PtP Param configuring interface
Currently no fix is available
- No fix availableFM Configuration Package
Currently no fix is available
- No fix availableModular PID CTRL Tool
Currently no fix is available
- No fix availableSIMATIC Energy Suite V17
Currently no fix is available
- No fix availableSIMATIC Energy Suite V18
Currently no fix is available
- No fix availableSIMATIC MTP Integrator V1.x
Currently no fix is available
- No fix availableSIMATIC MTP Integrator V2.x
Currently no fix is available
- No fix availableSIMATIC NET PC Software V16
Currently no fix is available
- No fix availableSIMATIC NET PC Software V17
Currently no fix is available
- No fix availableSIMATIC NET PC Software V18
Currently no fix is available
- No fix availableSIMATIC NET PC Software V19
Currently no fix is available
- No fix availableSIMATIC PCS 7 MPC Configurator
Currently no fix is available
- No fix availableSIMATIC ProSave V20
Currently no fix is available
- No fix availableSIMATIC Route Control V10.0
Currently no fix is available
- No fix availableSIMATIC Route Control V9.1
Currently no fix is available
- No fix availableSIMATIC STEP 7 V5.7
Currently no fix is available
- No fix availableSIMATIC WinCC Runtime Professional V20
Currently no fix is available
- No fix availableSIMATIC WinCC TeleControl
Currently no fix is available
- No fix availableSIMATIC WinCC Unified PC Runtime V18
Currently no fix is available
- No fix availableSIMATIC WinCC Unified PC Runtime V19
Currently no fix is available
- No fix availableSIMATIC WinCC Unified PC Runtime V20
Currently no fix is available
- No fix availableSIMATIC WinCC Visualization Architect (SiVArc) V18
Currently no fix is available
- No fix availableSIMATIC eaSie Core Package (6DL5424-0AX00-0AV8)
Currently no fix is available
- No fix availableSIMATIC eaSie Document Skills
Currently no fix is available
- No fix availableSIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8)
Currently no fix is available
- No fix availableSIMATIC eaSie Workflow Skills
Currently no fix is available
- No fix availableSIMIT Rapid Tester
Currently no fix is available
- No fix availableSIMIT Simulation Platform
Currently no fix is available
- No fix availableSINAMICS Startdrive V17
Currently no fix is available
- No fix availableSINAMICS Startdrive V18
Currently no fix is available
- No fix availableSINAMICS Startdrive V19
Currently no fix is available
- No fix availableSINAMICS Startdrive V20
Currently no fix is available
- No fix availableSINEMA Remote Connect Client
Currently no fix is available
- No fix availableSITRANS
Currently no fix is available
- No fix availableStandard PID CTRL Tool
Currently no fix is available
- FixedAutomation License Manager V6.2
Update to V6.2 Upd3 or later version
https://support.industry.siemens.com/cs/ww/en/view/114358/ - FixedCreate MyConfig (CMC)
Update to V6.9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955311/ - FixedMultiFieldbus Configuration Tool (MFCT)
Update to V1.5.5.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109773881/ - FixedSIMATIC Automation Tool
Update to V5.0 SP4 or later version
https://support.industry.siemens.com/cs/ww/en/view/110004631/ - FixedSIMATIC Automation Tool SDK Windows
Update to V5.0 SP4 or later version
https://support.industry.siemens.com/cs/ww/en/view/110004631/ - FixedSIMATIC Control Function Library (CFL) V3.x
Update to V3.1.0.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974209/ - FixedSIMATIC Control Function Library (CFL) V4.x
Update to V4.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109982975/ - FixedSIMATIC Energy Suite V19
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109947027/ - FixedSIMATIC Logon V2.0
Update to V2.0 Upd3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109983445/ - FixedSIMATIC MTP CREATOR V4.x
Update to V4.1.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925636/ - FixedSIMATIC MTP CREATOR V2.x
Update to V2.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109982993/ - FixedSIMATIC MTP CREATOR V5.x
Update to V5.0.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109982991/ - FixedSIMATIC Management Agent
Update to V9.1 SP1 Upd8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC Management Console
Update to V9.1 SP1 Upd8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC NET PC Software V20
Update to V20.0 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109987675/ - FixedSIMATIC PCS 7 Advanced Process Faceplates V9.1
Update to V9.1 SP2 Upd4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS 7 Advanced Process Library V9.1
Update to V9.1 SP2 Upd6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS 7 Basis Faceplates V9.1
Update to V9.1 SP2 Upd2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS 7 Basis Library V10.0
Update to V10.0 SP1 Upd2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109983445/ - FixedSIMATIC PCS 7 Basis Library V9.1
Update to V9.1 SP2 Upd8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS 7 Logic Matrix V9.1
Update to V9.1 Upd8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS 7 V10.0
Update to V10.0 SP1 UC01 or later version
https://support.industry.siemens.com/cs/ww/en/view/109983445/ - FixedSIMATIC PCS 7 V9.1
Update to V9.1 SP1 UC08 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC PCS neo V6.0
Update to V6.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109991149/ - FixedSIMATIC PDM V9.3
Update to V9.3 SP1 Upd2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109983445/ - FixedSIMATIC ProSave V17
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - FixedSIMATIC ProSave V19
Update to V19 Update 4 or later version
- FixedSIMATIC Process Historian 2024
Update to V2024 SP1 Upd2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109983445/ - FixedSIMATIC S7-1500 Software Controller V3
Update to V31.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478528/ - FixedSIMATIC S7-Fail-safe Configuration Tool (S7-FCT)
Update to V4.0.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109762827/ - FixedSIMATIC S7-PCT
Update to V3.5 SP4 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/32469496/ - FixedSIMATIC S7-PLCSIM Advanced
Update to V7.0 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109988436/ - FixedSIMATIC S7-PLCSIM V20
Update to V20 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109963851/ - FixedSIMATIC Target
Update to V6.0 SP3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109997133/ - FixedSIMATIC WinCC Runtime Advanced
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109800912/ - FixedSIMATIC WinCC Runtime Professional
Update to V21 or later version
https://support.industry.siemens.com/cs/ww/en/view/109991139/ - FixedSIMATIC WinCC Unified Line Coordination
Update to V20 or later version
https://support.industry.siemens.com/cs/ww/en/view/109987448/ - FixedSIMATIC WinCC Unified Sequence
Update to V20 or later version
https://support.industry.siemens.com/cs/ww/en/view/109987448/ - FixedSIMATIC WinCC V7.5
Update to V7.5 SP2 Update 20 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793460/ - FixedSIMATIC WinCC V8.0
Update to V8.0 Update 8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109818723/ - FixedSIMATIC WinCC V8.1
Update to V8.1 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977191/ - FixedSIMATIC WinCC Visualization Architect (SiVArc) V17
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109792356/ - FixedSIMATIC WinCC Visualization Architect (SiVArc) V19
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821883/ - FixedSIMATIC WinCC Visualization Architect (SiVArc) V20
Update to V20 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109974402/ - FixedSIMATIC D7-SYS
Update to V10.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/110003221/ - FixedSINEC NMS
Update to V4.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109989514/ - FixedSiemens Network Planner (SINETPLAN)
Update to V2.0 SP2 or later version
https://support.industry.siemens.com/cs/ww/en/view/110002597/ - FixedTIA Administrator
Update to V3.0.6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825038/ - FixedTIA Portal Cloud Connector
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109780755/ - FixedTIA Portal Test Suite V19
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - FixedTIA Portal Test Suite V20
Update to V20 Update 3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109963851/ - FixedTIA Project-Server
Update to V2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109810588/ - FixedTeleControl Server Basic V3.1
Update to V3.1.2.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109987362/ - FixedTotally Integrated Automation Portal (TIA Portal) V17
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - FixedTotally Integrated Automation Portal (TIA Portal) V18
Update to V18 Update 6 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817218/ - FixedTotally Integrated Automation Portal (TIA Portal) V19
Update to V19 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109925643/ - FixedTotally Integrated Automation Portal (TIA Portal) V20
Update to V20 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109963851/ - FixedWinCC Panel Image Setup
Update to V17 Update 9 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825750/
Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.
Free scan