VDE-2025-105

csafDEendress_hauser_psirt

Endress+Hauser: Multiple products affected by Wibu-Systems CodeMeter Vulnerability

view advisory published 2025-12-08

A vulnerability in Wibu-Systems CodeMeter (up to version 7.60b) affects multiple Endress+Hauser products. This flaw can lead to a heap buffer overflow, which may allow remote code execution under certain conditions.

01

describes (1)

Related CVEs.

IDseverity exploitable
CVE-2023-3935US——
A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of…
02

references

External citations — patches, advisories, analysis.

03

remediations (2)

  • Mitigation

    If possible, configure CodeMeter to run in client-only mode. If server mode is required, restrict access to authorized clients by implementing an access control list. For Proline Promag 800 OPC UA Connectivity, CodeMeter operates as a server only during license activation. Installation and license activation are managed by Endress+Hauser. If a customer performs manual license activation, it is strongly recommended to limit network access to necessary clients only by using firewalls or equivalent security measures.

  • Fixed

    Endress+Hauser has released updated firmware versions that address this vulnerability. Customers are strongly advised to upgrade to the latest fixed version. For assistance, please contact your local Endress+Hauser service center.

scry

Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.

Free scan