sca-2026-0011

csafDEsick_psirt

Vulnerabilities in Wibu Systems CodeMeter Runtime Affect Multiple SICK Products

view advisory published 2026-09-04

Several vulnerabilities in the Wibu Systems CodeMeter Runtime affect the SICK products Sentio Creator, Sentio Compose, Safety Designer, Stream Editor, CODE-LOC, LiDAR-LOC, PLB, SIM1200-2A1A130 LiDAR-LOC and multiple SICK Industrial PCs (APU0G00, APU0G50, APU0G03, APU3F00, APU4600, APU8G00 and APU8G20), which ship with CodeMeter Runtime as part of their preinstalled image. For Sentio Compose, Safety Designer, Stream Editor and PLB, only CVE-2026-81572 is relevant. Vulnerabilities requiring the CodeMeter Runtime to be configured as a server are not applicable to default Sentio Compose, Safety Designer, Stream Editor and PLB installations, as the runtime is shipped with the Network Server and CmWAN Server functionalities disabled. Customers who have modified the default configuration and enabled CodeMeter server functionality should review the remaining vulnerabilities for potential impact. The vulnerabilities could potentially affect the integrity, confidentiality, and availability of the affected products.

01

describes (5)

Related CVEs.

IDseverity exploitable
CVE-2026-81576US——
If configured as a server, CodeMeter Runtime before versions 8.41a and 9.10 issues handles per connection and relies on a cryptographically weak SID as sole authenticator. An attac…
CVE-2026-81575US——
If configured as a server, CodeMeter Runtime before versions 8.41a and 9.10 accepts requests with opcode 0x5e, which contain the data length and the data itself. Missing bounds che…
CVE-2026-81574US——
In CodeMeter Runtime before versions 8.41a and 9.10, the logger does not sanitize input strings in certain cases, allowing an attacker to inject printf-style format specifiers. Thi…
CVE-2026-81573US—OT elevated—
If CodeMeter Runtime before 8.41a or 9.10 is configured as a server, the configuration command handler does not enforce network- origin restrictions. Commands intended only for loc…
CVE-2026-81572US——
In CodeMeter Runtime from version 8.40 to (excluding) 8.41a and 9.00 to (excluding) 9.10, cmu.exe --create-io --file C: creates a predictable temporary file under C:\CM-Stick. The…
02

references

External citations — patches, advisories, analysis.

03

remediations (92)

  • MitigationSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources "SICK Operating Guidelines" and "ICS-CERT recommended practices on Industrial Security" could help to implement the general security practices.

  • MitigationSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources "SICK Operating Guidelines" and "ICS-CERT recommended practices on Industrial Security" could help to implement the general security practices.

  • MitigationSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources "SICK Operating Guidelines" and "ICS-CERT recommended practices on Industrial Security" could help to implement the general security practices.

  • MitigationSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources "SICK Operating Guidelines" and "ICS-CERT recommended practices on Industrial Security" could help to implement the general security practices.

  • FixedCODE-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedCODE-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedCODE-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedCODE-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedCODE-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedLiDAR-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedLiDAR-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedLiDAR-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedLiDAR-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedLiDAR-LOC

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.7 and Image ID 30

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.7 and Image ID 30

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.7 and Image ID 30

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.7 and Image ID 30

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G00 with Image Version 1.0.0.7 and Image ID 30

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.1 and Image ID 41

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.1 and Image ID 41

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.1 and Image ID 41

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.1 and Image ID 41

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.1 and Image ID 41

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.2 and Image ID 36

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.2 and Image ID 36

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.2 and Image ID 36

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.2 and Image ID 36

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G03 with Image Version 1.0.0.2 and Image ID 36

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.1 and Image ID 45

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.1 and Image ID 45

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.1 and Image ID 45

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.1 and Image ID 45

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.1 and Image ID 45

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU0G50 with Image Version 1.0.0.2 and Image ID 38

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 27

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 27

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 27

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 27

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 27

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 46

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 46

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 46

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 46

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU3F00 with Image Version 1.0.0.0 and Image ID 46

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU4600 with Image Version 1.1.0.1 and Image ID 18

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU4600 with Image Version 1.1.0.1 and Image ID 18

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU4600 with Image Version 1.1.0.1 and Image ID 18

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU4600 with Image Version 1.1.0.1 and Image ID 18

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU4600 with Image Version 1.1.0.1 and Image ID 18

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.11 and Image ID 15

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.11 and Image ID 15

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.11 and Image ID 15

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.11 and Image ID 15

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.11 and Image ID 15

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.2 and Image ID 44

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.2 and Image ID 44

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.2 and Image ID 44

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.2 and Image ID 44

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G00 with Image Version 1.0.0.2 and Image ID 44

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 29

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 29

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 29

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 29

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 29

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 32

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 32

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 32

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 32

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK APU8G20 with Image Version 1.0.0.2 and Image ID 32

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSICK PLB with all firmware versions

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSafety Designer

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • FixedSentio Compose

    Users are recommended to upgrade to version 2.1.0.

  • FixedSentio Creator

    Users are recommended to upgrade to version 2026.3.

  • FixedSentio Creator

    Users are recommended to upgrade to version 2026.3.

  • FixedSentio Creator

    Users are recommended to upgrade to version 2026.3.

  • FixedSentio Creator

    Users are recommended to upgrade to version 2026.3.

  • FixedSentio Creator

    Users are recommended to upgrade to version 2026.3.

  • FixedStream Editor

    Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

  • WorkaroundSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Customers should block unauthorized access to ports 22350 and 22352.

  • WorkaroundSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Customers should block unauthorized access to ports 22350 and 22352.

  • WorkaroundSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Customers should block unauthorized access to ports 22350 and 22352.

  • WorkaroundSICK SIM1200-2A1A130 LiDAR-LOC with all firmware versions

    Customers should block unauthorized access to ports 22350 and 22352.