Vulnerabilities affecting SICK Lector85x and SICK Lector83x
Two vulnerabilities affecting the SICK Lector85x and SICK Lector83x product families have been identified. Both vulnerabilities are caused by insufficient access restrictions in HTTP-based interfaces, which may allow unauthenticated access to sensitive device resources. Depending on the configuration, this could lead to unauthorized modification of device settings and security-relevant data. SICK recommends applying the defined remediations for both vulnerabilities. SICK is currently not aware of any public exploits.
describes (2)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2026-2331US | — | — | ||
An attacker may perform unauthenticated read and write operations on sensitive filesystem areas via the AppEngine Fileaccess over HTTP due to improper access restrictions. A critic… | ||||
| CVE-2026-2330US | — | — | ||
An attacker may access restricted filesystem areas on the device via the CROWN REST interface due to incomplete whitelist enforcement. Certain directories intended for internal tes… | ||||
references
External citations — patches, advisories, analysis.
remediations (4)
- FixedSICK Lector83x with firmware < 2.8.0
Users are strongly recommended to upgrade to release version 2.8.0.
- FixedSICK Lector83x with firmware >= 2.6.0 <= 2.7.0
Users are strongly recommended to upgrade to release version 2.8.0.
- FixedSICK Lector85x with firmware < 2.8.0
Users are strongly recommended to upgrade to release version 2.8.0.
- FixedSICK Lector85x with firmware >= 2.6.0 <= 2.7.0
Users are strongly recommended to upgrade to release version 2.8.0.