SCA-2023-0006

csafDEsick_psirt

Vulnerabilities in SICK ICR890-4

view advisory published 2023-07-10

SICK has found several security vulnerabilities in the SICK ICR890-4. If exploited, these could allow an unauthenticated remote attacker to compromise the availability or confidentiality of the SICK ICR890-4. Currently, SICK is not aware of any public exploits that specifically target any of the vulnerabilities. SICK has released a new version of the SICK ICR890-4 firmware and recommends updating to the latest version.

01

describes (8)

Related CVEs.

IDseverity exploitable
CVE-2023-3273UShigh7.5—
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to affect the availability of the device by changing settings of the device such as the…
CVE-2023-3272UShigh7.5OT elevated—
Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a remote attacker to gather sensitive information by intercepting network traffic that is not encry…
CVE-2023-3271UShigh7.5—
Improper Access Control in the SICK ICR890-4 could allow an unauthenticated remote attacker to gather information about the system and download data via the REST API by accessing u…
CVE-2023-3270UShigh7.5—
Exposure of Sensitive Information to an Unauthorized Actor in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the system.
CVE-2023-35699USmedium4.6OT elevated—
Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card.
CVE-2023-35698USmedium5.3—
Observable Response Discrepancy in the SICK ICR890-4 could allow a remote attacker to identify valid usernames for the FTP server from the response given during a failed login atte…
CVE-2023-35697UShigh7.5—
Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4 could allow a remote attacker to brute-force user credentials.
CVE-2023-35696UShigh7.5—
Unauthenticated endpoints in the SICK ICR890-4 could allow an unauthenticated remote attacker to retrieve sensitive information about the device via HTTP requests.
02

references

External citations — patches, advisories, analysis.

03

remediations (8)

  • MitigationSICK ICR890-4 with Firmware <V2.5.0

    Please make sure that you apply general security practices when operating the SICK ICR890-4 like restricting physical access to the device. The following general security practices could mitigate the associated security risk.

  • FixedSICK ICR890-4 with Firmware <V2.5.0

    The recommended solution is to update the firmware to a version >= V2.5.0 as soon as possible.

  • FixedSICK ICR890-4 with Firmware <V2.5.0

    The recommended solution is to update the firmware to a version >= V2.5.0 as soon as possible.

  • FixedSICK ICR890-4 with Firmware <V2.5.0

    The recommended solution is to update the firmware to a version >= V2.5.0 as soon as possible.

  • FixedSICK ICR890-4 with Firmware <V2.5.0

    The recommended solution is to update the firmware to a version >= V2.5.0 as soon as possible.

  • WorkaroundSICK ICR890-4 with Firmware <V2.5.0

    SICK recommends to disable port 2111 & 2122 once the SICK ICR890-4 is put into operation.

  • WorkaroundSICK ICR890-4 with Firmware <V2.5.0

    SICK recommends to disable port 2111 & 2122 once the SICK ICR890-4 is put into operation.

  • WorkaroundSICK ICR890-4 with Firmware <V2.5.0

    SICK recommends to disable port 2111 & 2122 once the SICK ICR890-4 is put into operation.