SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server
SINEC NMS and SINEMA Server V14 contain multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens has released several updates for SINEC NMS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
describes (3)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2022-25311US | medium6.5 | — | ||
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not… | ||||
| CVE-2022-24282US | medium6.5 | — | ||
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected system allows to… | ||||
| CVE-2022-24281US | medium6.5 | — | ||
A vulnerability has been identified in SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). A privileged authenticated attacker could execute arbitrary commands in… | ||||
references
External citations — patches, advisories, analysis.
- SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - CSAF Versionself
- SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - HTML Versionself
- SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - PDF Versionself
- SSA-250085: Multiple Vulnerabilities in SINEC NMS and SINEMA Server - TXT Versionself
remediations (14)
- MitigationSINEC NMS
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- MitigationSINEC NMS
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- MitigationSINEC NMS
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- MitigationSINEMA Server V14
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- MitigationSINEMA Server V14
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- MitigationSINEMA Server V14
Restrict access to the affected systems, especially to port 443/tcp, to trusted IP addresses only
- No fix plannedSINEMA Server V14
Currently no fix is planned
- No fix plannedSINEMA Server V14
Currently no fix is planned
- No fix plannedSINEMA Server V14
Currently no fix is planned
- FixedSINEC NMS
Update to V1.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109813788/ - FixedSINEC NMS
Update to V1.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109813788/ - FixedSINEC NMS
Update to V1.0.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109813788/ - WorkaroundSINEC NMS
CVE-2022-25311: If SSO was established and user is authenticated in both Control and Operation, it is recommended to logout explicitly in both Control and Operation to avoid privilege escalation
- WorkaroundSINEMA Server V14
CVE-2022-25311: If SSO was established and user is authenticated in both Control and Operation, it is recommended to logout explicitly in both Control and Operation to avoid privilege escalation
Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.