view advisory published 2020-04-14

The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

01

describes (1)

Related CVEs.

IDseverity exploitable
CVE-2019-19301USmedium5.0—
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCA…
02

references

External citations — patches, advisories, analysis.

03

remediations (230)

  • MitigationSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204-2 (6GK5204-2BB10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204-2FM (6GK5204-2BB11-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204-2LD (6GK5204-2BC10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204-2TS (6GK5204-2BB10-2CA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204IRT (6GK5204-0BA00-2BA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X206-1 (6GK5206-1BB10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X206-1LD (6GK5206-1BC10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X208 (6GK5208-0BA10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X208PRO (6GK5208-0HA10-2AA6)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X212-2 (6GK5212-2BB00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X212-2LD (6GK5212-2BC00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X216 (6GK5216-0BA00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X224 (6GK5224-0BA00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X304-2FE (6GK5304-2BD00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-3 (6GK5307-3BL00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-3 (6GK5307-3BL10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-3LD (6GK5307-3BM00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X307-3LD (6GK5307-3BM10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2 (6GK5308-2FL00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2 (6GK5308-2FL10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LD (6GK5308-2FM00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LD (6GK5308-2FM10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LH (6GK5308-2FN00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LH (6GK5308-2FN10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M (6GK5308-2GG00-2AA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M (6GK5308-2GG10-2AA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M TS (6GK5308-2GG00-2CA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X308-2M TS (6GK5308-2GG10-2CA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X310 (6GK5310-0FA00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X310 (6GK5310-0FA10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X310FE (6GK5310-0BA00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X310FE (6GK5310-0BA10-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X320-1 FE (6GK5320-1BD00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE X408-2 (6GK5408-2FD00-2AA2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF204 (6GK5204-0BA00-2AF2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF204-2 (6GK5204-2BC00-2AF2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF204IRT (6GK5204-0BA00-2BF2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF206-1 (6GK5206-1BC00-2AF2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XF208 (6GK5208-0BA00-2AF2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 442-1 RNA (6GK7442-1RX00-0XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 443-1 (6GK7443-1EX30-0XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 443-1 (6GK7443-1EX30-0XE1)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC CP 443-1 RNA (6GK7443-1RX00-0XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC RF180C (6GT2002-0JD00)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIMATIC RF182C (6GT2002-0JD10)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • MitigationSIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)

    For SIMATIC RF180C and RF182C: migrate to a successor product within the SIMATIC RF18xC/CI family, V1.3 or later version. For details refer to the phase-out announcement.

  • No fix plannedSIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0)

    Currently no fix is planned

  • No fix plannedSIMATIC RF180C (6GT2002-0JD00)

    Currently no fix is planned

  • No fix plannedSIMATIC RF182C (6GT2002-0JD10)

    Currently no fix is planned

  • No fix plannedSIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0)

    Currently no fix is planned

  • FixedSCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X202-2IRT (6GK5202-2BB00-2BA3)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X204-2 (6GK5204-2BB10-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X204-2FM (6GK5204-2BB11-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X204-2LD (6GK5204-2BC10-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X204-2LD TS (6GK5204-2BC10-2CA2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X204-2TS (6GK5204-2BB10-2CA2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X204IRT (6GK5204-0BA00-2BA3)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE X206-1 (6GK5206-1BB10-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X206-1LD (6GK5206-1BC10-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X208 (6GK5208-0BA10-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X208PRO (6GK5208-0HA10-2AA6)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X212-2 (6GK5212-2BB00-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X212-2LD (6GK5212-2BC00-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X216 (6GK5216-0BA00-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X224 (6GK5224-0BA00-2AA3)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X304-2FE (6GK5304-2BD00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X306-1LD FE (6GK5306-1BF00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-3 (6GK5307-3BL00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-3 (6GK5307-3BL10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-3LD (6GK5307-3BM00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X307-3LD (6GK5307-3BM10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2 (6GK5308-2FL00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2 (6GK5308-2FL10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LD (6GK5308-2FM00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LD (6GK5308-2FM10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LH (6GK5308-2FN00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LH (6GK5308-2FN10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LH+ (6GK5308-2FP00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2LH+ (6GK5308-2FP10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M (6GK5308-2GG00-2AA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M (6GK5308-2GG10-2AA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M PoE (6GK5308-2QG00-2AA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M PoE (6GK5308-2QG10-2AA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M TS (6GK5308-2GG00-2CA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X308-2M TS (6GK5308-2GG10-2CA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X310 (6GK5310-0FA00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X310 (6GK5310-0FA10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X310FE (6GK5310-0BA00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X310FE (6GK5310-0BA10-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X320-1 FE (6GK5320-1BD00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE X408-2 (6GK5408-2FD00-2AA2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE XF204 (6GK5204-0BA00-2AF2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE XF204-2 (6GK5204-2BC00-2AF2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE XF204IRT (6GK5204-0BA00-2BF2)

    Update to V5.5.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109792534/
  • FixedSCALANCE XF206-1 (6GK5206-1BC00-2AF2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE XF208 (6GK5208-0BA00-2AF2)

    Update to V5.2.5 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801131/
  • FixedSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
  • FixedSIMATIC CP 442-1 RNA (6GK7442-1RX00-0XE0)

    Update to V1.5.18 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808794
  • FixedSIMATIC CP 443-1 (6GK7443-1EX30-0XE0)

    Update to V3.3 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109817938/
  • FixedSIMATIC CP 443-1 (6GK7443-1EX30-0XE1)

    Update to V3.3 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109817938/
  • FixedSIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0)

    Update to V3.3 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109817938/
  • FixedSIMATIC CP 443-1 RNA (6GK7443-1RX00-0XE0)

    Update to V1.5.18 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808796
  • FixedSIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0)

    Update to V3.3 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109817938/
  • FixedSIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0)

    Update to V3.3 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109817938/
  • FixedSIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3)

    Update to V4.1.4 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109808359/
scry

Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.

Free scan