SSA-433782: Improper Access Control Vulnerability in Mendix
An improper access control vulnerability in Mendix applications was discovered. In case of access to an active user session, the vulnerability could allow to change that user’s password bypassing password validations within a Mendix application. Siemens has released updates for the affected products and recommends to update to the latest versions.
describes (1)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2022-31257US | high7.5 | — | ||
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applicatio… | ||||
references
External citations — patches, advisories, analysis.
remediations (5)
- FixedMendix Applications using Mendix 7
Update your Mendix Project to V7.23.31 or later version and redeploy your application
https://docs.mendix.com/releasenotes/studio-pro/7/ - FixedMendix Applications using Mendix 8
Update your Mendix Project to V8.18.18 or later version and redeploy your application
https://docs.mendix.com/releasenotes/studio-pro/8/ - FixedMendix Applications using Mendix 9
Update your Mendix Project to V9.14 or later version and redeploy your application
https://docs.mendix.com/releasenotes/studio-pro/9/ - FixedMendix Applications using Mendix 9 (V9.12)
Update your Mendix Project to V9.12.2 or later version and redeploy your application
https://docs.mendix.com/releasenotes/studio-pro/9.12/ - FixedMendix Applications using Mendix 9 (V9.6)
Update your Mendix Project to V9.6.12 or later (preferably to the latest V9.12 version) and redeploy your application
https://docs.mendix.com/releasenotes/studio-pro/9.6/
Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.