SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products
Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
describes (1)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2020-0543US | medium5.5 | — | ||
Incomplete cleanup from specific special register read operations in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local… | ||||
references
External citations — patches, advisories, analysis.
- SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - CSAF Versionself
- SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - PDF Versionself
- SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products - TXT Versionself
remediations (50)
- MitigationSIMATIC Field PG M4
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC Field PG M5
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC Field PG M6
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC3000 SMART V2
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC347E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC427D (incl. SIPLUS variants)
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC427E (incl. SIPLUS variants)
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC477D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC477E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC477E Pro
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC527G
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC547E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC547G
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC627D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC627E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC647D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC647E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC677D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC677E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC827D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC847D
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC IPC847E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMATIC ITP1000
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMOTION P320-4E
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- MitigationSIMOTION P320-4S
Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity
- No fix plannedSIMATIC Field PG M4
Currently no remediation is planned
- No fix plannedSIMATIC IPC347E
Currently no remediation is planned
- No fix plannedSIMATIC IPC427D (incl. SIPLUS variants)
Currently no remediation is planned
- No fix plannedSIMATIC IPC477D
Currently no remediation is planned
- No fix plannedSIMATIC IPC547E
Currently no remediation is planned
- No fix plannedSIMATIC IPC627D
Currently no remediation is planned
- No fix plannedSIMATIC IPC647D
Currently no remediation is planned
- No fix plannedSIMATIC IPC677D
Currently no remediation is planned
- No fix plannedSIMATIC IPC827D
Currently no remediation is planned
- No fix plannedSIMATIC IPC847D
Currently no remediation is planned
- No fix plannedSIMOTION P320-4E
Currently no remediation is planned
- No fix plannedSIMOTION P320-4S
Currently no remediation is planned
- FixedSIMATIC Field PG M5
Update BIOS to V22.01.08
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC Field PG M6
Update BIOS to V26.01.07
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC3000 SMART V2
Update BIOS to V1.B or later version
https://support.industry.siemens.com/cs/cn/en/view/109763408/ - FixedSIMATIC IPC427E (incl. SIPLUS variants)
Update BIOS to V21.01.14
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC477E
Update BIOS to V21.01.14
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC477E Pro
Update BIOS to V21.01.14
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC527G
Update BIOS to V1.4.0
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC547G
Update BIOS to R1.28.0
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC627E
Update BIOS to V25.02.06
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC647E
Update BIOS to V25.02.06
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC677E
Update BIOS to V25.02.06
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC IPC847E
Update BIOS to V25.02.06
https://support.industry.siemens.com/cs/ww/en/view/109763408 - FixedSIMATIC ITP1000
Update BIOS to V23.01.08
https://support.industry.siemens.com/cs/ww/en/view/109763408