SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products

view advisory published 2021-07-13

WIBU Systems published information about two vulnerabilities and an associated fix release version of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens products for license management. The vulnerabilities are described in the section "Vulnerability Classification" below and got assigned the CVE IDs CVE-2021-20093 and CVE-2021-20094. Successful exploitation of these vulnerabilities could allow an attacker to read data from the heap of the CodeMeter Runtime network server, or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

01

describes (2)

Related CVEs.

IDseverity exploitable
CVE-2021-20094UShigh7.5—
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server…
CVE-2021-20093UScritical9.1—
A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or cr…
02

references

External citations — patches, advisories, analysis.

03

remediations (23)

  • MitigationPSS(R)CAPE

    If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.

  • MitigationPSS(R)CAPE

    If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.

  • MitigationSICAM 230

    Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.

  • MitigationSICAM 230

    Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.

  • MitigationSIMATIC Information Server

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running.

  • MitigationSIMATIC PCS neo

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running.

  • MitigationSIMATIC Process Historian (incl. Process Historian OPC UA Server)

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running.

  • MitigationSIMATIC WinCC OA V3.17

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running (for details refer to the updated security manual of WinCC OA).

  • MitigationSIMATIC WinCC OA V3.18

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running (for details refer to the updated security manual of WinCC OA).

  • MitigationSINEC INS

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running. Note that this is the default configuration, which therefore limits the exploitability to local attacks only.

  • MitigationSINEMA Remote Connect Server

    Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running. Note that this is the default configuration, which therefore limits the exploitability to local attacks only.

  • No fix plannedSICAM 230

    Currently no remediation is planned

  • No fix plannedSICAM 230

    Currently no remediation is planned

  • FixedPSS(R)CAPE

    CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.

  • FixedPSS(R)CAPE

    CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.

  • FixedSIMATIC Information Server

    Update SIMATIC PCS neo to V3.1 or later version

  • FixedSIMATIC PCS neo

    Update to V3.1 or later version

  • FixedSIMATIC Process Historian (incl. Process Historian OPC UA Server)

    Update SIMATIC PCS neo to V3.1 or later version

  • FixedSIMATIC WinCC OA V3.17

    Update to V3.17 P013 or later version

    https://www.winccoa.com/downloads/category/versions-patches.html
  • FixedSIMATIC WinCC OA V3.18

    Update to V3.18 P002 or later version

    https://www.winccoa.com/downloads/category/versions-patches.html
  • FixedSIMIT Simulation Platform

    Alternatively, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.wibu.com/us/support/user/downloads-user-software.html and follow the installation instructions from WIBU Systems.

    https://support.industry.siemens.com/cs/ww/en/view/109800638/
  • FixedSINEC INS

    Alternatively, update CodeMeter Runtime to V7.21a: Download the package "CodeMeter User Runtime for Linux, version 7.21a, Driver-only" from the WIBU Systems User Software website. Install it on the system which runs SINEC INS by executing the following command: "sudo dpkg --force-depends --force-confnew -i codemeter-7.21.4611.501_amd64.deb"

    https://support.industry.siemens.com/cs/ww/en/view/109806100/
  • FixedSINEMA Remote Connect Server

    Update to V3.0 SP2 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109793790/
scry