ICSA-25-140-07

icsaUScisa_csaf_ot

Schneider Electric Galaxy VS, Galaxy VL, Galaxy VXL (Update A)

view advisory published 2025-05-13

Schneider Electric is aware of a vulnerability disclosed on the Erlang/OTP's SSH Server component used Schneider Electric Galaxy VS, VL, and VXL.Many vendors, including Schneider Electric, embed the Erlang/OTP's SSH Server in their offers.The Galaxy VS, Galaxy VL, Galaxy VXL products are 3-phase UPS for data centers and other business critical applications.Failure to apply the mitigation provided below may risk unauthenticated remote code execution (RCE), which could impact the monitoring capabilities of the UPS and potential UPS operation.

01

describes (1)

Related CVEs.

IDseverity exploitable
CVE-2025-32433US—OT criticalKEV
Erlang/OTP is a set of libraries for the Erlang programming language. Prior to versions OTP-27.3.3, OTP-26.2.5.11, and OTP-25.3.2.20, a SSH server may allow an attacker to perform…
02

references

External citations — patches, advisories, analysis.

03

remediations (6)

  • MitigationGalaxy VL

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: 1. Log on to the NMC4 via the Web Interface. Once logged into the system, navigate to the Console settings page from the menu bar by selecting Configuration -> Network -> Console -> Access 2. From the Console setting screen, uncheck the enable SSH/SFTP/SCP check box -> Click Apply As an alternative, setup network segmentation and implement a firewall to block all unauthorized access to SSH port 22/TCP. If assistance is needed applying the above mitigation, please contact our technical support team: https://www.se.com/ww/en/work/support/ To learn more, we recommend reviewing the Network Management Card 4 Security Handbook for specific actions available here to secure your devices further: https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/ To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric's security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp

    https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/
  • MitigationGalaxy VS

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: 1. Log on to the NMC4 via the Web Interface. Once logged into the system, navigate to the Console settings page from the menu bar by selecting Configuration -> Network -> Console -> Access 2. From the Console setting screen, uncheck the enable SSH/SFTP/SCP check box -> Click Apply As an alternative, setup network segmentation and implement a firewall to block all unauthorized access to SSH port 22/TCP. If assistance is needed applying the above mitigation, please contact our technical support team: https://www.se.com/ww/en/work/support/ To learn more, we recommend reviewing the Network Management Card 4 Security Handbook for specific actions available here to secure your devices further: https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/ To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric's security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp

    https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/
  • MitigationGalaxy VXL

    If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: 1. Log on to the NMC4 via the Web Interface. Once logged into the system, navigate to the Console settings page from the menu bar by selecting Configuration -> Network -> Console -> Access 2. From the Console setting screen, uncheck the enable SSH/SFTP/SCP check box -> Click Apply As an alternative, setup network segmentation and implement a firewall to block all unauthorized access to SSH port 22/TCP. If assistance is needed applying the above mitigation, please contact our technical support team: https://www.se.com/ww/en/work/support/ To learn more, we recommend reviewing the Network Management Card 4 Security Handbook for specific actions available here to secure your devices further: https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/ To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric's security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp

    https://www.se.com/us/en/download/document/SPD_CCON-B8EJSJ_EN/
  • FixedGalaxy VL

    Version 18.10.0 of Galaxy VL includes a fix for this vulnerability and is available through your local FSR by contacting Schneider Electric's Customer Care Center.

  • FixedGalaxy VS

    Version 6.123.0 of Galaxy VS includes a fix for this vulnerability and is available through your local FSR by contacting Schneider Electric's Customer Care Center.

  • FixedGalaxy VXL

    Version 15.29.0 of Galaxy VXL includes a fix for this vulnerability and is available through your local FSR by contacting Schneider Electric's Customer Care Center.