Siemens SCALANCE LPE9403
view advisory published 2023-05-09
SCALANCE LPE9403 is affected by multiple vulnerabilities that could allow an attacker to impact its confidentiality, integrity and availability. Siemens has released an update for the SCALANCE LPE9403 and recommends to update to the latest version.
01
describes (4)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2023-27410US | — | — | ||
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will… | ||||
| CVE-2023-27409US | low3.3 | — | ||
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This cou… | ||||
| CVE-2023-27408US | — | — | ||
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The `i2c` mutex file is created with the permissions bits of `-rw-rw-rw-`. This file is used as a mut… | ||||
| CVE-2023-27407US | critical9.9 | — | ||
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The web based management of affected device does not properly validate user input, making it suscepti… | ||||
02
references
External citations — patches, advisories, analysis.
- SSA-325383: Multiple Vulnerabilities in SCALANCE LPE9403 before V2.1 - CSAF Versionself
- SSA-325383: Multiple Vulnerabilities in SCALANCE LPE9403 before V2.1 - HTML Versionself
- SSA-325383: Multiple Vulnerabilities in SCALANCE LPE9403 before V2.1 - PDF Versionself
- SSA-325383: Multiple Vulnerabilities in SCALANCE LPE9403 before V2.1 - TXT Versionself
- ICS Advisory ICSA-23-131-06 JSONself
- Recommended Practicesexternal
- ICS Advisory ICSA-23-131-06 - Web Versionself
- Recommended Practicesexternal
03
remediations (4)
- FixedSCALANCE LPE9403 (6GK5998-3GS00-2AC2)
Update to V2.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817856/ - FixedSCALANCE LPE9403 (6GK5998-3GS00-2AC2)
Update to V2.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817856/ - FixedSCALANCE LPE9403 (6GK5998-3GS00-2AC2)
Update to V2.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817856/ - FixedSCALANCE LPE9403 (6GK5998-3GS00-2AC2)
Update to V2.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109817856/