ICSA-24-116-04

icsaUScisa_csaf_ot

Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, Safety Manager SC

view advisory published 2024-04-25

Successful exploitation of these vulnerabilities could disclose sensitive information, allow privilege escalation, or allow remote code execution.

01

describes (16)

Related CVEs.

IDseverity exploitable
CVE-2023-5407US——
Controller denial of service due to improper handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgradi…
CVE-2023-5406US——
Server communication with a controller can lead to remote code execution using a specially crafted message from the controller. See Honeywell Security Notification for recommendati…
CVE-2023-5405US——
Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for r…
CVE-2023-5404US——
Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure. See Honeywell Security Notification for recommend…
CVE-2023-5403US——
Server hostname translation to IP address manipulation which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification f…
CVE-2023-5401US——
Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execu…
CVE-2023-5400US——
Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execut…
CVE-2023-5398US——
Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upg…
CVE-2023-5397US——
Server receiving a malformed message to create a new connection could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification…
CVE-2023-5396US——
Server receiving a malformed message creates connection for a hostname that may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notificat…
CVE-2023-5395US——
Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Noti…
CVE-2023-5394US——
Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell r…
CVE-2023-5393US——
Server receiving a malformed message that causes a disconnect to a hostname may causing a stack overflow resulting in possible remote code execution. Honeywell recommends updating…
CVE-2023-5392US——
C300 information leak due to an analysis feature which allows extracting more memory over the network than required by the function. Honeywell recommends updating to the most recen…
CVE-2023-5390USmedium5.3—
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be…
CVE-2023-5389UShigh7.5—
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit co…