ICSA-22-349-18

icsaUScisa_csaf_ot

Siemens SCALANCE SC-600 Family

view advisory published 2022-12-13

Multiple vulnerabilities affecting various third-party components of the SCALANCE SC-600 family could allow an attacker to cause a denial of service condition, corrupt memory or potentially execute custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.

01

describes (4)

Related CVEs.

IDseverity exploitable
CVE-2022-32206USmedium6.5—
curl < 7.84.0 supports "chained" HTTP compression algorithms, meaning that a serverresponse can be compressed multiple times and potentially with different algorithms. The number o…
CVE-2022-32205USmedium4.3—
A malicious server can serve excessive amounts of `Set-Cookie:` headers in a HTTP response to curl and curl < 7.84.0 stores all of them. A sufficiently large amount of (big) cookie…
CVE-2022-30065UShigh7.8—
A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.
CVE-2018-25032UShigh7.5Exploit
zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches.
02

references

External citations — patches, advisories, analysis.

03

remediations (24)

scry

Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.

Free scan