ICSA-20-212-02_Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A)
Younes Dragoni of Nozomi Networks, the Applied Risk research team, and Mashav Sapir of Claroty reported this vulnerability to Mitsubishi Electric.
describes (1)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2020-14496US | critical9.8 | — | ||
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escal… | ||||
references
External citations — patches, advisories, analysis.
remediations (62)
- MitigationCPU Module Logging Configuration Tool
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationCW Configurator
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationData Transfer
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationEZSocket
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationFR Configurator2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationGT SoftGOT1000 Version3
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationGT SoftGOT2000 Version1 Bersions
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationGX LogViewer
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationGX Works2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationGX Works3
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMELFA-Works
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMELSEC WinCPU Setting Utility
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMELSOFT EM Software Development Kit (EM Configurator)
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMELSOFT FieldDeviceConfigurator
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMELSOFT Navigator
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMH11 SettingTool Version2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMI Configurator
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMR Configurator2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMT Works2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMX Component
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationM_CommDTM-HART
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationM_CommDTM-IO-Link
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationMotorizer
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationNetwork Interface Board CC IE Control utility
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationNetwork Interface Board CC IE Field Utility
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationNetwork Interface Board CC-Link Ver.2 Utility
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationNetwork Interface Board MNETH utility
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationPX Developer
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationRT ToolBox2
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationRT ToolBox3
CPU Module Logging Configuration Tool, Version 1.106K or later
- MitigationSetting/monitoring tools for the C Controller module (SW4PVC-CCPU)
CPU Module Logging Configuration Tool, Version 1.106K or later
- FixedCPU Module Logging Configuration Tool
MT Works2, Version 1.160S or later
- FixedCW Configurator
MT Works2, Version 1.160S or later
- FixedData Transfer
MT Works2, Version 1.160S or later
- FixedEZSocket
MT Works2, Version 1.160S or later
- FixedFR Configurator2
MT Works2, Version 1.160S or later
- FixedGT SoftGOT1000 Version3
MT Works2, Version 1.160S or later
- FixedGT SoftGOT2000 Version1 Bersions
MT Works2, Version 1.160S or later
- FixedGX LogViewer
MT Works2, Version 1.160S or later
- FixedGX Works2
MT Works2, Version 1.160S or later
- FixedGX Works3
MT Works2, Version 1.160S or later
- FixedMELFA-Works
MT Works2, Version 1.160S or later
- FixedMELSEC WinCPU Setting Utility
MT Works2, Version 1.160S or later
- FixedMELSOFT EM Software Development Kit (EM Configurator)
MT Works2, Version 1.160S or later
- FixedMELSOFT FieldDeviceConfigurator
MT Works2, Version 1.160S or later
- FixedMELSOFT Navigator
MT Works2, Version 1.160S or later
- FixedMH11 SettingTool Version2
MT Works2, Version 1.160S or later
- FixedMI Configurator
MT Works2, Version 1.160S or later
- FixedMR Configurator2
MT Works2, Version 1.160S or later
- FixedMT Works2
MT Works2, Version 1.160S or later
- FixedMX Component
MT Works2, Version 1.160S or later
- FixedM_CommDTM-HART
MT Works2, Version 1.160S or later
- FixedM_CommDTM-IO-Link
MT Works2, Version 1.160S or later
- FixedMotorizer
MT Works2, Version 1.160S or later
- FixedNetwork Interface Board CC IE Control utility
MT Works2, Version 1.160S or later
- FixedNetwork Interface Board CC IE Field Utility
MT Works2, Version 1.160S or later
- FixedNetwork Interface Board CC-Link Ver.2 Utility
MT Works2, Version 1.160S or later
- FixedNetwork Interface Board MNETH utility
MT Works2, Version 1.160S or later
- FixedPX Developer
MT Works2, Version 1.160S or later
- FixedRT ToolBox2
MT Works2, Version 1.160S or later
- FixedRT ToolBox3
MT Works2, Version 1.160S or later
- FixedSetting/monitoring tools for the C Controller module (SW4PVC-CCPU)
MT Works2, Version 1.160S or later
Advisories like this name the exposed products attackers go after on your perimeter. See what is exposed on your perimeter with a free passive scan.