Siemens SINAMICS (Update C)
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
describes (1)
Related CVEs.
| ID | severity | exploitable | ||
|---|---|---|---|---|
| CVE-2019-6568US | medium5.0 | — | ||
The webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a denial of service
situation which leads to… | ||||
references
External citations — patches, advisories, analysis.
- SSA-530931: Denial-of-Service in Webserver of Industrial Products - HTML Versionself
- ICS Advisory ICSA-19-227-04 JSONself
- Recommended Practicesexternal
- ICS Advisory ICSA-19-227-04 - Web Versionself
- Recommended Practicesexternal
- Recommended Practicesexternal
- Recommended Practicesexternal
- Recommended Practicesexternal
remediations (21)
- MitigationSINAMICS GH150 V4.7 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS GH150 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS GL150 V4.7 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS GL150 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS GM150 V4.7 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS GM150 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS SL150 V4.7 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS SL150 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS SM120 V4.7 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS SM120 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- MitigationSINAMICS SM150 V4.8 (Control Unit)
Apply appropriate strategies for mitigation as described in the General Security Recommendation section.
- FixedSINAMICS GH150 V4.7 (Control Unit)
Upgrade to V4.8 SP2 HF9 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS GH150 V4.8 (Control Unit)
Upgrade to V4.8 SP2 HF9 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS GL150 V4.7 (Control Unit)
Upgrade to V4.8 SP2 HF9 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS GL150 V4.8 (Control Unit)
Upgrade to V4.8 SP2 HF9 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS GM150 V4.8 (Control Unit)
Upgrade to V4.8 SP2 HF9 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS SL150 V4.7 (Control Unit)
Update to V4.7 HF33 or upgrade to V5.2 SP2. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS SL150 V4.8 (Control Unit)
Upgrade to V5.2 SP2. The software can be obtained from your Siemens representative or via Siemens customer service
- FixedSINAMICS SM120 V4.7 (Control Unit)
Upgrade to V4.8 SP2 HF10 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS SM120 V4.8 (Control Unit)
Upgrade to V4.8 SP2 HF10 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.
- FixedSINAMICS SM150 V4.8 (Control Unit)
Upgrade to V5.1 SP2 HF3 or later version. The software can be obtained from your Siemens representative or via Siemens customer service.